AEFM-001 Atmospheric Electric Field Meter
- Manufacturer: DPF Sensors
- Category: Meteorology – Climatology, SENSORS, Several
For lightning monitoring and early warning, the DPF Sensors AEFM-001 is an atmospheric electric field meter that measures in real time the electric field variations associated with lightning activity.
It measures from -100 to +100 kV/m with a response time of 3 seconds and transmits the field strength value in V/m, rotational speed, and alarm level via Modbus RS-485. It has three configurable thresholds: 3, 8, and 10 kV/m by default. When the field exceeds a threshold, the alarm level rises to 1, 2, or 3.
It is used in weather stations (providing reference information for sectors such as aviation and maritime operations), petrochemical plants, communications base stations, electrical installations, high-rise buildings, agriculture, and forestry. The housing is made of 6061 aluminum alloy, measuring Ø78 × 105 mm, and connects with a 4-wire shielded cable. Available in guemisa.es.
- Range of −100 to +100 kV/m with a response time of 3 s.
- 3 alarm levels with thresholds of 3, 8 and 10 kV/m by default, modifiable via Modbus.
- Modbus RS-485 with speeds of 2400 to 115200 and default address 245.
- Consumption of 0.8 W at 12V and motor life of up to 4000 h without overloading or blocking.
Technical Frequently Asked Questions
How does the AEFM-001 generate the lightning alert?
It compares the measured electric field with three thresholds, 3, 8, and 10 kV/m by default. When the field exceeds a threshold, the alarm level register (0x0008) is set to 1, 2, or 3. The thresholds are modified by writing to registers 0x000A, 0x000C, and 0x000E.
How is the electric field read by Modbus?
Using function 03 on register 0x0006, which is 4 bytes, the value is in V/m, with one decimal place by default. The default address is 245 and the transmission speed is chosen in register 0x0004, between 2400 and 115200.
How do I connect the AEFM-001?
With a shielded 4-wire cable: red, power; blue, GND; green, 485B; yellow, 485A. The specifications indicate 12V DC (0.8W at 12V) and the cable color code, 12~24V DC: please confirm with Guemisa before ordering.
Properties
| Feature | Specification |
|---|---|
| Extent | |
| Measuring range | -100 … +100 kV/m |
| Precision | ±0.001 % FS. |
| Response time | 3 s |
| Reading the field | In V/m, with one decimal place by default |
| Alarm levels | 3 / 8 / 10 kV/m default, configurable thresholds |
| Food and communication | |
| Feeding | 12 V DC 0.8 W at 12 V; 12~24 V DC depending on the wiring (confirm with Guemisa before ordering) |
| Communication | Modbus RS-485 |
| Default address | 245 |
| Transmission speed | 2400 … 115200 2400, 4800, 9600, 19200, 38400 or 115200 |
| Wire | 4 shielded wires: red +, blue GND, green 485B, yellow 485A |
| Mechanics and environment | |
| Rotation speed | ≥ 50 rpm in normal operation |
| Engine life | 4000 h at most, without overload or blocking |
| Housing material | 6061 Aluminum Alloy |
| Dimensions | Ø78 × 105 mm dimensions 75 mm and Ø38 mm |
| Facility | Protect from impacts, high temperatures and freezing; ensure watertightness |