Digital indicator and MAP-4000 conditioner
- Manufacturer: Novotechnik
- Category: Signal converters, Digital indicators, INSTRUMENTATION, Processes, Resistance and Potentiometers
Novotechnik MAP-4000 digital indicator and conditioner. Multifunction indicator with processor for potentiometers, standardized signals, and temperature sensors.
Digital panel indicator with 24-bit Sigma-Delta A/D converter. Inputs: potentiometer, process voltage and current (0…10 V, 4…20 mA), resistance, RTD and Ni probes, T/C thermocouples. Sensor excitation from 5 to 24 V DC. Programming via 5 front panel keys or serial interface.
Key points
- 6-digit LED display (-99 999…999 999) with a height of 14 mm
- 24-bit Sigma-Delta Converter with ±0.1 accuracy %
- Integrated adjustable auxiliary power supply from 5 to 24 V DC (up to 1.2 W)
- Universal input: potentiometer, ±10 V / 0…40 V, 0/4…20 mA and Pt, Ni and T/C thermocouple probes
- Options: analog output, up to 4 relays, RS 232 / RS 485 bus and data logger
- Panel mount 96 x 48 x 120 mm with IP65 front panel
Technical Frequently Asked Questions
What sensors and signals can be connected to the MAP-4000 digital indicator and conditioner?
Supports potentiometer (DU): track resistance min. 500Ω; voltage (DC): 0…60 / 150 / 300 mV; process voltage (PM): ±2 V, ±5 V, ±10 V / 0…40 V; process current (PM): 0…5 mA or 0/4…20 mA; resistance (OHM): 0…100 / 1k / 10k / 100 kΩ or 5…105 Ω; platinum probes (RTD): Pt 100 / Pt 500 / Pt 1 000; nickel (Ni) probes: Ni 1,000 / Ni 10,000; thermocouples (T/C): J/K/T/E/B/S/R/N.
How do I order the MAP-4000 digital indicator and conditioner?
For example, MAP 4010 · 000 · 101 is the version with an 80…250 V AC/DC power supply, without relays, without analog output, without interface, with excitation, without register, and with a red display. All order references with their corresponding part numbers are listed in the reference table on this page.
Under what conditions does the MAP-4000 digital indicator and conditioner operate?
Operating temperature: 0…60 °C. Protection: IP65 on the front.
Properties
| Feature | Specification |
|---|---|
| Tickets | |
| Potentiometer (DU) | Minimum track resistance 500 Ω |
| Voltage (DC) | 0…60 / 150 / 300 mV |
| Process voltage (PM) | ±2 V, ±5 V, ±10 V / 0…40 V |
| Process stream (PM) | 0…5 mA or 0/4…20 mA |
| Resistance (OHM) | 0…100 / 1k / 10k / 100 kΩ or 5…105 Ω |
| Platinum probes (RTD) | Pt 100 / Pt 500 / Pt 1000 |
| Nickel (Ni) probes | Not 1,000 / Not 10,000 |
| Thermocouples (T/C) | J/K/T/E/B/S/R/N |
| RTD and Ohm Connection | 2, 3 or 4 wires |
| Cold junction compensation (T/C) | Adjustable 0…99 °C or automatic |
| Sensor excitation | 5…24 V DC adjustable (max. 1.2 W) |
| Measurement and display | |
| A/D Converter | 24-bit Sigma-Delta |
| Display | 6-digit red LED (-99999…999999, h = 14 mm) |
| Basic accuracy | ±0.1 % of the range + 1 digit (at 5 measurements/s) |
| Temperature accuracy | ±0.15 % of the range + 1 digit (RTD, T/C) |
| Measurement rate | 0.1…40 measurements/s |
| Temperature coefficient | 100 ppm/°K |
| Functions | |
| Digital filter | Exponential mean (configurable between 2 and 100 measurements) |
| Rounding | Incremental rounding |
| Measurement functions | Offset, min./max. value, tare, peak value |
| Mathematical functions | Polynomials, 1/x, logarithm, exponential, square root, sin(x) |
| Unit on display | The last two digits may indicate the unit |
| Decimal point and brightness | Adjustable in menu |
| External control | HOLD (measurement lock), LOCK (key lock) and Store inputs |
| Overload | 10x (max 30ms); at >400 V, 5 A: 2x |
| Watchdog | The device restarted after 1.2 seconds. |
| Food and environment | |
| Feeding | 10…30 V AC/DC or 80…250 V AC/DC, ±10 %, 10 VA |
| Food protection | Internal fuse |
| Dimensions | 96 x 48 x 120 mm |
| Hole in panel | 90.5 x 45 mm |
| Housing | Noryl GFN2 SE 1, non-flammable according to UL94 VI |
| Protection | IP65 on the front |
| Working temperature | 0…60 °C |
| Storage temperature | -10…85 °C |
| Reference | Configuration |
|---|---|
| MAP-4000-000-101MAP4000000101 | Art. 400055824 · Configuration (order code fields): 10…30 V AC/DC · without relays · without analog output · without interface · without registration |
| MAP-4000-001-101MAP4000001101 | Art. 400055810 · Configuration (order code fields): 10…30 V AC/DC · without relays · without analog output · RS 232 · without register |
| MAP-4000-001-111MAP4000001111 | Art. 400105753 · Configuration (order code fields): 10…30 V AC/DC · without relays · without analog output · RS 232 · RTC register |
| MAP-4000-002-111MAP4000002111 | Art. 400106643 · Configuration (order code fields): 10…30 V AC/DC · without relays · without analog output · RS 485 · RTC register |
| MAP-4000-010-101MAP4000010101 | Art. 400055822 · Configuration (order code fields): 10…30 V AC/DC · without relays · with analog output · without interface · without registration |
| MAP-4000-011-101MAP4000011101 | Art. 400055823 · Configuration (order code fields): 10…30 V AC/DC · without relays · with analog output · RS 232 · without register |
| MAP-4000-011-121MAP4000011121 | Art. 400055826 · Configuration (order code fields): 10…30 V AC/DC · without relays · with analog output · RS 232 · FAST register |
| MAP-4000-200-101MAP4000200101 | Art. 400055804 · Configuration (order code fields): 10…30 V AC/DC · 2 closing relays · no analog output · no interface · no registration |
| MAP-4000-201-101MAP4000201101 | Art. 400055815 · Configuration (order code fields): 10…30 V AC/DC · 2 closing relays · no analog output · RS 232 · no registration |
| MAP-4000-201-111MAP4000201111 | Art. 400107286 · Configuration (order code fields): 10…30 V AC/DC · 2 closing relays · no analog output · RS 232 · RTC register |
| MAP-4000-210-101MAP4000210101 | Art. 400106774 · Configuration (order code fields): 10…30 V AC/DC · 2 closing relays · with analog output · without interface · without registration |
| MAP-4000-211-121MAP4000211121 | Art. 400055827 · Configuration (order code fields): 10…30 V AC/DC · 2 closing relays · with analog output · RS 232 · FAST register |
| MAP-4000-400-101MAP4000400101 | Art. 400055809 · Configuration (order code fields): 10…30 V AC/DC · 4 relays · no analog output · no interface · no registration |
| MAP-4000-401-101MAP4000401101 | Art. 400103965 · Configuration (order code fields): 10…30 V AC/DC · 4 relays · no analog output · RS 232 · no registration |
| MAP-4000-401-111MAP4000401111 | Art. 400106041 · Configuration (order code fields): 10…30 V AC/DC · 4 relays · no analog output · RS 232 · RTC register |
| MAP-4000-410-101MAP4000410101 | Art. 400108154 · Configuration (order code fields): 10…30 V AC/DC · 4 relays · with analog output · without interface · without registration |
| MAP-4000-411-111MAP4000411111 | Art. 400107216 · Configuration (order code fields): 10…30 V AC/DC · 4 relays · with analog output · RS 232 · RTC register |
| MAP-4010-000-101MAP4010000101 | Art. 400055805 · Configuration (order code fields): 80…250 V AC/DC · without relays · without analog output · without interface · without registration |
| MAP-4010-001-101MAP4010001101 | Art. 400055828 · Configuration (order code fields): 80…250 V AC/DC · without relays · without analog output · RS 232 · without register |
| MAP-4010-002-101MAP4010002101 | Art. 400055818 · Configuration (order code fields): 80…250 V AC/DC · without relays · without analog output · RS 485 · without register |
| MAP-4010-002-121MAP4010002121 | Art. 400107726 · Configuration (order code fields): 80…250 V AC/DC · without relays · without analog output · RS 485 · FAST register |
| MAP-4010-010-101MAP4010010101 | Art. 400055802 · Configuration (order code fields): 80…250 V AC/DC · without relays · with analog output · without interface · without registration |
| MAP-4010-011-101MAP4010011101 | Art. 400055832 · Configuration (order code fields): 80…250 V AC/DC · without relays · with analog output · RS 232 · without register |
| MAP-4010-011-111MAP4010011111 | Art. 400055833 · Configuration (order code fields): 80…250 V AC/DC · without relays · with analog output · RS 232 · RTC register |
| MAP-4010-011-121MAP4010011121 | Art. 400055825 · Configuration (order code fields): 80…250 V AC/DC · without relays · with analog output · RS 232 · FAST register |
| MAP-4010-012-101MAP4010012101 | Art. 400055814 · Configuration (order code fields): 80…250 V AC/DC · without relays · with analog output · RS 485 · without register |
| MAP-4010-012-111MAP4010012111 | Art. 400103929 · Configuration (order code fields): 80…250 V AC/DC · without relays · with analog output · RS 485 · RTC register |
| MAP-4010-200-101MAP4010200101 | Art. 400055807 · Configuration (order code fields): 80…250 V AC/DC · 2 closing relays · no analog output · no interface · no registration |
| MAP-4010-201-101MAP4010201101 | Art. 400055829 · Configuration (order code fields): 80…250 V AC/DC · 2 closing relays · no analog output · RS 232 · no registration |
| MAP-4010-201-111MAP4010201111 | Art. 400104559 · Configuration (order code fields): 80…250 V AC/DC · 2 closing relays · no analog output · RS 232 · RTC register |
| MAP-4010-210-101MAP4010210101 | Art. 400055803 · Configuration (order code fields): 80…250 V AC/DC · 2 closing relays · with analog output · without interface · without registration |
| MAP-4010-211-101MAP4010211101 | Art. 400105751 · Configuration (order code fields): 80…250 V AC/DC · 2 closing relays · with analog output · RS 232 · without registration |
| MAP-4010-211-111MAP4010211111 | Art. 400055819 · Configuration (order code fields): 80…250 V AC/DC · 2 closing relays · with analog output · RS 232 · RTC register |
| MAP-4010-212-101MAP4010212101 | Art. 400106169 · Configuration (order code fields): 80…250 V AC/DC · 2 closing relays · with analog output · RS 485 · without registration |
| MAP-4010-400-101MAP4010400101 | Art. 400055820 · Configuration (order code fields): 80…250 V AC/DC · 4 relays · no analog output · no interface · no registration |
| MAP-4010-401-101MAP4010401101 | Art. 400055813 · Configuration (order code fields): 80…250 V AC/DC · 4 relays · no analog output · RS 232 · no registration |
| MAP-4010-410-101MAP4010410101 | Art. 400055830 · Configuration (order code fields): 80…250 V AC/DC · 4 relays · with analog output · without interface · without registration |
| MAP-4010-412-101MAP4010412101 | Art. 400055821 · Configuration (order code fields): 80…250 V AC/DC · 4 relays · with analog output · RS 485 · without registration |

Documentación, casos y guías relacionados
Technical documentation
- Catálogo general Novotechnik: sensores de posición lineales y angulares
- Definiciones técnicas de potenciómetros: linealidad, RGV e histéresis
- Sensores de posición Novotechnik con interfaz IO-Link
- Sensores de posición para válvulas y actuadores: series Novotechnik
- Sensores Novotechnik lineales y rotativos para automoción
Other products