TFD-4000 short-stroke contactless Hall transducer
- Manufacturer: Novotechnik
- Category: Displacement, SENSORS, Linear Transducers
Novotechnik TFD-4000 contactless Hall transducer. NOVOHALL technology, contactless.
Non-contact linear Hall effect transducer (NOVOHALL), in two parts: sensor and magnetic position marker. Ratiometric analog output of 0.25–4.75 V. Measuring ranges from 0–5 to 0–50 mm. Resolution up to 12 bits. IP67, IP68, IP69 protection; temperature range -40 to +125 °C.
Key points
- Two-piece design, mechanically decoupled
- IP67, IP68, IP69 protection
- Resolution up to 12 bits
Technical Frequently Asked Questions
What can be connected to the TFD-4000 contactless Hall transducer?
It can be connected to positioners (magnets and cursors) for Novotechnik linear sensors.
How do I order the TFD-4000 contactless Hall transducer?
The order code has 7 fields: mechanical version, channels, range (mm), power supply, signal, characteristic, and connection. For example, TFD-4021-614-211-401 (Art. 400104212) is a single-channel device, 0…8 mm to 0…14 mm, 5 VDC, ratiometric 5…95 %, rising characteristic, and 3 wires of 0.5 m. All order references with their corresponding Art. are listed in the reference table on this page.
Under what conditions does the TFD-4000 contactless Hall transducer operate?
Operating temperature: -40 … +125 °C. Protection: IP67 / IP68 / IP69.
Properties
| Feature | Specification |
|---|---|
| Description | |
| Housing | Temperature-resistant PBT GF plastic, with brass bushings |
| Mounting | 2 M4x14 socket head cap screws (included) |
| Tightening torque of the fastener | 250 ± 50 Ncm |
| Electrical connection | 0.5 mm² (AWG 20) PVC wires |
| Ground (no connection) | approx. 10 g |
| Made to order | Other ranges from 0…5 mm to 0…50 mm, other output characteristics, other wire lengths and mounted connectors |
| Electrical data | |
| Exit sign | ratiometric to the supply voltage Ub |
| Output signal margin | 5 … 95 % (0.25 … 4.75 V) in the electrical range (level L) |
| Burden | ≥ 10 kΩ |
| Number of channels | 1 / 2 |
| Update frequency | typical 2.5 kHz |
| Resolution | 12 bits |
| Repeatability | ≤ ±0.1 % FS |
| Hysteresis | ≤ ±0.1 % FS |
| Temperature error | ±0.5 % FS |
| Supply voltage Ub | 5 VDC (4.5 … 5.5 VDC) |
| No-load current consumption | typ. 15 mA (typ. 8 mA, on request) |
| Reverse polarity protection | Yes (feed lines) |
| Short circuit protection | Yes (all outputs connected to GND and the supply voltage) |
| Insulation resistance (500 VDC) | ≥ 10 MΩ |
| Environmental conditions | |
| Maximum working speed | Mechanically unlimited |
| Vibration IEC 60068-2-6 | 20 g, 5 … 2000 Hz, Amax = 0.75 mm |
| IEC 60068-2-27 Shock | 50 g, 6 ms |
| DIN EN 60529 protection | IP67 / IP68 / IP69 |
| Working temperature | -40 … +125 °C |
| Life | Mechanically unlimited |
| Functional safety | The sensor is not suitable for security-related applications. |
| MTTF (IEC 60050), a channel | 9926 years |
| MTTF (IEC 60050), partially redundant, per channel | 4441 years |
| MTTF (IEC 60050), fully redundant, per channel | 4512 years |
| Electromagnetic compatibility | |
| ISO 10605 ESD (handling) | 8 kV |
| ISO 10605 ESD (component) | 15 kV |
| ISO 11452-2 Radiated HF fields | 200 V/m |
| ISO 11452-5 Radiated HF fields, stripline | 200 V/m |
| CISPR 25 Radiated emission | Level 5 |
| EN 61000-4-4 Fast transients (burst) | 1 kV |
| EN 61000-4-6 Conducted disturbances (HF fields) | 10 V ef. |
| EN 61000-4-8 Magnetic fields | 30 A/m |
| Reference | Configuration |
|---|---|
| TFD-4021-614-211-401TFD4021614211401 | Art. 400104212 · Range: 0 … 8 to 0 … 14 mm · Channels: One channel |
| TFD-4021-624-211-401TFD4021624211401 | Art. 400104213 · Range: 0 … 15 up to 0 … 24 mm · Channels: One channel |
| TFD-4021-714-213-411TFD4021714213411 | Art. 400104217 · Range: 0 … 8 to 0 … 14 mm · Channels: Partially redundant |
| TFD-4021-724-213-411TFD4021724213411 | Art. 400104218 · Range: 0 … 15 to 0 … 24 mm · Channels: Partially redundant |
| TFD-4021-814-214-421TFD4021814214421 | Art. 400104221 · Range: 0 … 8 to 0 … 14 mm · Channels: Fully redundant |
| TFD-4021-824-214-421TFD4021824214421 | Art. 400104222 · Range: 0 … 15 to 0 … 24 mm · Channels: Fully redundant |


Related documentation, cases, and guides
Technical documentation
- Novotechnik General Catalogue: Linear and Angular Position Sensors
- Technical definitions of potentiometers: linearity, RGV and hysteresis
- Novotechnik position sensors with IO-Link interface
- Position sensors for valves and actuators: Novotechnik series
- Novotechnik linear and rotary sensors for automotive applications
Other products