CapSync HVT Module | High Voltage Temperature Meter 1000 Vrms | CAN Bus

Type K Thermocouple | -200…1200 °C | 1000 Vrms Insulation | 50 Hz CAN Sampling | IP20/IP66

The modular system CapSync HVT Atesteo pushes the boundaries of thermal measurement into high-voltage environments unexplored by conventional rotary transducers. Designed with millimeter precision not as a trailing device, but as a critical monitoring barrier, it is certified under IEC 61326-1 to capture the thermal ramp of electric motors (e-axles), inverters, fuel cells, and grid systems at uninterrupted sampling rates of 50 Hz per channel. Its DIN rail architecture enables tactical modularity: from the lightweight unit Variant -1/2 (2 active channels) up to the industrial battery Variant -4/8 (8 active channels).

Its greatest achievement lies not in the wide-spectrum thermal reading (-200 to 1,200 °C) through LEMO connections for Type K thermocouples, but in its Active Dielectric WallThe bridge electronics are strictly isolated to absorb lethal transient overvoltages of up to 6,000 Vpk and operate continuously under fields of 1,000 Vrms (Measurement Category CAT III). This electromagnetic shield allows room engineers to couple multiple devices. CapSync By linking the 24 VDC supply and the 2.0A CAN Bus node, we create pass-through analysis ecosystems invulnerable to the erratic spikes of next-generation automotive systems. Organize the thermal topology of your test benches by contacting the E-Mobility engineers at headquarters. Gemissa Acquisition Systems.

Properties

Module Deployment VariantsVariant -1/2 (2 LEMO Channels) | Variant -4/8 (8 Active Channels)
Operating Temperature SpectrumExtended scale from -200 °C to 1,200 °C (Type K thermocouple)
Active Isolation CategoryCAT III (Constant Operation at 1,000 Vrms / 1,500 Vpk)
Surge protectionTransient Support / Surge Test up to 6,000 Vpk
Electronic Nominal Metrological Rigor≤ ± 1.00 K (0.10 K Digital Matrix Resolution)
CAN Bus Network Ecosystem (Pass-through)Type 2.0A Modular (Scalable baud rates 250 / 500 / 1,000 kbit/s)
Bank Insertion FormatDIN rail profile with internal transmission bus (IP20 – IP66 optional)
Sampling Operating FrequencyFixed Analytical Latency at 50 Samples per Second and Channel (1/s 50)
Electromagnetic Protection of GradeStrict Approval IEC 61326-1 / DIN EN 61010-1
CapSync HVT Temperature Measurement System ATESTEO High Voltage Maximum Safety
CapSync HVT Module Dimensions ATESTEO Modular Technical Drawing

Other products

I/120 – Incremental Encoder Ø 120 mm, solid shaft Ø 22 mm × 73 mm, robust metal body, resolution up to 2,540 dpi
I/38S Miniature Incremental Encoder, shaft diameter 6.35×10, housing diameter ø 38×45.5, Pulse range: 1÷2540
LOGO TORQUE CERTIFICATION
Digital Optical Acquisition | 30,000 – 50,000 N·m | 5,500 RPM | PCD Flange 290.0 mm | Inertia 0.5695 kg·m²
Wire displacement sensor, ranges from 4000 mm to 20000 mm, with output signal in 5 Kohm resistance, 0-5 / 10 Vdc, 4-20 mA, RS485 or pulses, option with IP67 environmental protection
B&C ELECTRONICS Logo 2026 WATER QUALITY
Combined glass/gel reference pH electrode, 9.5mm diameter Epoxy body and 1.5m cable with BNC connector.
Wall-mounted temperature sensors for indoor or outdoor use, with Pt100, 4-20 mA, 0-10 Vdc signal, with or without display
Universal tensile-compression load cell, from 15 to 5000 kg. 2 mv/v.
HIGH temperature transducer
I/92CD – Incremental Encoder Ø 92 mm, through shaft Ø 20 mm, high-precision metal body, resolution up to 900,000 dpi