SSI TP1 profile magnetostrictive transducer
- Manufacturer: Novotechnik
- Category: Displacement, SENSORS, Magnetostrictive Linear Transducer, Linear Transducers
Novotechnik TP1 SSI magnetostrictive transducer. NOVOSTRICTIVE technology, non-contact.
Profile magnetostrictive transducer for non-contact linear position measurement. Stroke from 50 to 4250 mm. IP67/IP68 protection. Floating or guided position marker.
Key points
- Unlimited mechanical life
- Resolution down to 1 µm, independent of length
- Temperature coefficient ≤ 15 ppm/K
- Shock 100 g (11 ms); vibration 20 g
- IP67 / IP68 protection
- Same series with analog, SSI, pulse, incremental, CANopen and IO-Link interfaces: see their datasheets
Technical Frequently Asked Questions
What can be connected to the SSI TP1 magnetostrictive transducer?
It can be connected to Novotechnik M12 connectors and cables, Novotechnik M16 connectors and cables, Novotechnik linear sensor couplings and fixings, and Novotechnik linear sensor positioners (magnets and cursors).
How do I order the SSI TP1 magnetostrictive transducer?
The order code has six fields: stroke (mm), mechanical version, interface, signal, resolution, and code and connection. For example, TP1-0800-101-211-102 is the version with an 800 mm electrical range, profile design, 24-bit SSI, binary code with 5 µm resolution, and an 8-pin M12x1 connector. All the options for each field are available in the order code configurator on this page.
Under what conditions does the SSI TP1 magnetostrictive transducer operate?
Operating temperature: -40 … +85 °C. Protection: IP67.
Properties
| Feature | Specification |
|---|---|
| Description | |
| Housing | Anodized aluminum AlMgSi0.5 F22, 3.3206.71 |
| End flanges | Aluminum G AlSi12Cu1 (FE) |
| Mounting | Adjustable cable ties (included) |
| Placeholder | Floating, made of plastic; or guided, made of plastic, with articulated coupling |
| Electrical connection | M12x1 8-pole shielded connector; M16x0.75 (IEC 130-9) 6, 7 or 8-pole shielded connector; 8x 0.25 mm² shielded PUR cable, 1, 3 or 5 m |
| Electronics | SMD with integrated ASIC; the connector housing (display) is bonded to the sensor housing; the housing is capacitively decoupled from the electronics |
| Electrical data | |
| Electrical range (dimension B) | 0050 … 4250 mm |
| Protocol | 24-bit and 25-bit SSI (26-bit on request) |
| Tickets | RS422 |
| Monoflop time™ | 30 µs |
| Coding | Gray, binary |
| Sampling frequency (update) | < 750mm: 2kHz; 750 … < 2000 mm: 1 kHz; > 2000mm: 0.5kHz; extrapolated to 16 kHz |
| Resolution (LSB) | 1, 5 or 10 µm (other resolutions available upon request) |
| Absolute linearity (*), length < 250 mm | ≤ ±25 µm |
| Absolute linearity (*), length < 750 mm | ≤ ±30 µm |
| Absolute linearity (*), length < 1000 mm | ≤ ±50 µm |
| Absolute linearity (*), length < 2500 mm | ≤ ±80 µm |
| Absolute linearity (*), length up to 4250 mm | ≤ ±120 µm |
| Electrical zero point tolerance | ±0.5 mm |
| Reproducibility (rounded to the LSB) | ≤ 6 µm |
| Hysteresis (rounded to the LSB) | ≤ 4 µm |
| Temperature error | ≤ 15 ppm/K (min. 0.01 mm/K) |
| Supply voltage | 24 (13 … 34) VDC |
| Power supply voltage ripple | ≤ 10 % Ub |
| Overvoltage protection | 40 VDC (permanent) |
| Current consumption | ≤ 100 mA |
| Reverse polarity protection | Yes, up to the maximum supply voltage. |
| Short circuit protection | Yes (outputs to GND and supply voltage up to 7V) |
| Ohmic load at the outlets | > 120 Ω |
| Max clock frequency. | 2 MHz |
| Maximum clock frequency, cable < 5 m | 2000 kHz |
| Maximum clock frequency, cable < 30 m | 1000 kHz |
| Maximum clock frequency, cable < 100 m | 400 kHz |
| Maximum clock frequency, cable < 140 m | 300 kHz |
| Maximum clock frequency, cable < 230 m | 200 kHz |
| Maximum clock frequency, cable < 480 m | 100 kHz |
| Insulation resistance (500 VDC) | ≥ 10 MΩ |
| Mechanical data | |
| Electrical range (dimension B) | 0050 … 0500 mm in 25 mm increments; 500 … 1000 mm in 50 mm increments; 1000 … 2000 mm in 100 mm increments; 2000 … 4250 mm in 250 mm increments; other lengths available upon request |
| Housing length (dimension A) | dimension B + 146 mm |
| Maximum operating speed with valid output signal | 10 m/s |
| Maximum operating acceleration with valid output signal | 200 m/s² |
| IEC 60068-2-27 Shock | 100 g (11 ms), one stroke |
| Vibration IEC 60068-2-6 | 20 g (5 … 2000 Hz, Amax = 0.75 mm) |
| DIN EN 60529 protection, with fixed connector | IP67 |
| DIN EN 60529 protection, with cable | IP68 |
| Life | Mechanically unlimited (with floating placeholder) |
| Working temperature | -40 … +85 °C |
| Storage temperature | -40 … +105 °C |
| Working humidity | 0 … 95 % HR (non-condensing) |
| Safety and compliance | |
| MTTF (IEC 60050) | 313 years |
| Accordance | EC |
| Electromagnetic compatibility | |
| EN 61000-4-2 | Electrostatic discharges (ESD) 4 kV, 8 kV |
| EN 61000-4-3 | Electromagnetic fields 10 V/m |
| EN 61000-4-4 | Fast transients (burst) 2 kV |
| EN 61000-4-6 | Conducted disturbances induced by RF fields 10 V rms. |
| EN 55011 | Radiated disturbances, class B |
| Option | Meaning |
|---|---|
| Example: TP1-0800-101-211-102 = 800 mm electrical range, profile design, 24-bit SSI, 5 µm resolution binary code, and 8-pole M12x1 connector. | |
| 1. Electrical range (mm) | |
| 0050 … 4250 | Steps from 25 mm to 500, from 50 mm to 1000, from 100 mm to 2000 and from 250 mm to 4250; other lengths available upon request |
| 2 · Mechanical version | |
| 101 | Profile design |
| 3 · Electrical interface | |
| 2 | SSI |
| 4 · SSI output signal (2__) | |
| 1 | SSI 24 bit |
| 2 | SSI 25 bit |
| 7 | SSI 26 bit (25 = alarm, 26 = even parity), on request |
| 5 · Synchronous serial interface (2__) | |
| 1 | Binary code; resolution 5 µm |
| 2 | Gray code; 5 µm resolution |
| 4 | Binary code; resolution 1 µm |
| 5 | Gray code; resolution 1 µm |
| 7 | Binary code; resolution 10 µm |
| 8 | Gray code; resolution 10 µm |
| 6. Electrical connection | |
| 101 | Connector M16x0.75 (IEC 130-9), 8 poles |
| 102 | M12x1 connector, 8 poles |
| 103 | Connector M16x0.75 (IEC 130-9), 6 poles |
| 108 | M16x0.75 connector (IEC 130-9), 7-pin (SSI only) |
| 201 | 8-wire cable, shielded, 1 m |
| 203 | 8-wire cable, shielded, 3 m |
| 205 | 8-wire cable, shielded, 5 m |
| The code is formed using one option from each field, in the order shown in the example. Contact us and we will confirm the exact reference. | |


Related documentation, cases, and guides
Technical documentation
- Novotechnik General Catalogue: Linear and Angular Position Sensors
- Technical definitions of potentiometers: linearity, RGV and hysteresis
- Novotechnik position sensors with IO-Link interface
- Position sensors for valves and actuators: Novotechnik series
- Novotechnik linear and rotary sensors for automotive applications
Other products