MTN/CA003 Online Load Amplifier

Load to Voltage Converter | Passive Input (No Amp) | Analog mV Output (Amp) | Gain 1pC = 2mV | Impedance >10^12 Ohms | Frequency 1Hz-20kHz | Power Supply 18-30V DC | Microdot/SMC to BNC Connection | Shielded Housing | In-Line Mounting

The conditioner MTN/CA003 It is an in-line load amplifier specifically designed to convert the high-impedance (picocoulomb) output signal from passive accelerometers into a low-voltage (millivolt) signal. This device acts as the required amplification stage for the P Series and P1100, allowing the dynamic readings generated in the high-temperature region to be processed by standard data acquisition systems, oscilloscopes, or spectrum analyzers.

At the electronic architecture level, the CA003 operates with a predetermined gain of 1 pC = 2 mV and has an input impedance greater than 10^12 ohms. This high coupling impedance is critical to minimize signal attenuation due to parasitic capacitance and ensure strict response linearity from 1 Hz to 20 kHz. The module requires an external DC power supply between 18 V and 30 V to bias its internal circuitry and generate the voltage signal (Amp).

Housed in a 20×65 mm cylindrical enclosure to minimize electromagnetic interference (EMI), the device is physically sandwiched between the sensor (outside the extreme heat zone) and the reading equipment. It supports input configuration via Microdot (10-32 UNF) or SMC connectors for low-noise cable, delivering the conditioned analog signal through an industry-standard female BNC port.

  • Charge to Voltage Conversion which allows passive sensors to be integrated into conventional analysis platforms.
  • High coupling impedance to avoid distortions due to the capacitance of the coaxial cable.
  • "In-Line" topology« which facilitates mounting outside the hostile thermal environment of the transducer.
  • Asymmetrical power supply of 18-30V DC for compatibility with standard industrial power supplies.

Technical Frequently Asked Questions

1. Where should the amplifier be installed relative to the sensor?
The CA003 does not tolerate extreme temperatures. It must be located at a safe distance from the heat source (outside the 250°C environment of the passive sensor), connected using a heat-resistant, low-noise coaxial cable.
2. Can it operate with adjustable gain?
The factory default gain is fixed (1pC = 2mV) to ensure maximum stability in loop calibration. Alternative gain configurations are available upon request.
3. Is it compatible with passive sensors from other brands?
Yes, the CA003 can condition the signal from any piezoelectric load-output transducer, provided that the input impedance and gain range are compatible with the sensor's sensitivity.

Properties

FeatureTechnical Specification
TechnologyIn-Line Signal Conditioner
Input Signal (Sensor)Passive Charge Output (Charge – pC)
Output Signal (Reading)Analog Voltage (mV)
Nominal Fixed Profit1 pC = 2 mV
Bandwidth (Frequency)1 Hz to 20 kHz
Input Impedance>1012 Ohms
Supply Voltage (VDC)18V to 30V DC
Input ConnectorMicrodot (10-32 UNF) or SMC
Output ConnectorBNC Female
Nominal Dimensions20mm (diameter) x 65mm (length)
Housing MaterialAluminum / Stainless Steel (EMI Armored)
Structural Mass45 grams
MTN/CA003 in-line load amplifier with Microdot and BNC connectors.
Technical dimensions and wiring diagram of the MTN/CA003 amplifier.

Other products

3-way isolator: 0/10V input, isolated excitation (24V/20mA), isolated 0/10V output, isolated 24VDC (20.. 30V) power supply
OBD-II GPS tracker with 4G LTE Cat 1, OEM data reading and Plug & Play installation
Monitran-Logo
Output 10-100mV/g | Frequency 2Hz-10kHz | Isolated AC Output | Temperature -55 to 140°C | IP67 Protection | Stainless Steel | Top Input | Insulated Base | Power Supply 15-28V | ETFE Cable
Monitran-Logo
Simultaneous XYZ Axes | Stainless Steel | M12 4-Pin Connector | 100mV/g Sensitivity | 2Hz-10kHz Frequency | Isolated AC Outputs | IP67 Protection | ±80g Range | IEPE Power Supply | Temperature: -55 to 140°C
Amplifier for proportional solenoid valves, voltage regulation (speed)
4G GPS tracker with integrated CAN for reading data from vehicles, fleets, and electric vehicles
Dimetix_AG-1
Precision Mechanical Support for Laser Aiming Range: Mechanical adjustment of +/- 4° on two axes for stable readings at long distances
Ethernet to RS485 Modbus RTU/TCP-IP Multi-Client Isolator Converter
NPN/PNP to relay pickup power supply, PNP/NPN to potential-free contact output adapter
8-channel 0-4/20mA statically switching multiplexer
Shopping Basket