MTN/5000 Monitoring System

12 Analog Channel Monitoring | 3.5″ TFT Touchscreen | 12-bit Sampling Resolution | Sampling Rate up to 1MHz | Voltage / 4-20mA Inputs | Front BNC Outputs (AC Signal) | Modbus TCP/IP Communication | 12 Configurable Alarms | IP65 GRP Housing | 24V DC / 100-240V AC Power Supply

Data dispersion among multiple isolated sensors on the plant floor critically delays intervention in the event of an abnormal increase in vibration or temperature. Relying solely on manual inspection routes increases the risk of unexpected mechanical failure in continuously rotating equipment.

To centralize the control of these signals, this unit processes and numerically displays readings from up to 12 sensors in real time. Using its touch interface, the operator assigns independent alarm thresholds and delay times for each channel, thus preventing the main relay from malfunctioning in response to natural transient spikes during machine startup.

Its electronics are housed in an insulated glass fiber reinforced polyester (GRP) enclosure, simplifying its structured field installation. By universally accepting 4-20mA analog signals and voltage, it allows for the unified electromechanical status of pumps, fans, and direct drive units at a single point.

  • unified management of 12 analog readings.
  • Processing to 12 bits with peak speeds of up 250 KHz.
  • Visualization in 3.5″ TFT touchscreen (graphs, meter or bars).
  • Global electrical power supply range of 100 to 240V AC.
  • Temporary storage using 12 x 100 sample buffer.

Technical Frequently Asked Questions

1. Does the system store the behavior prior to an alarm?
Yes. The internal buffer allows the last 100 samples acquired per channel to be retained. This makes it possible to project a trend graph (plot) on the screen to observe the mechanical degradation curve detected before the safety trigger.

2. Can you send your logs to the network installed on the plant?
By integrating the communication module Modbus TCP/IP, The system organically maps the logs of the 12 channels so that they can be read by any centralized SCADA software, allowing remote viewing of the status of the assets.

3. Does it allow for in-depth spectral analysis of the engines?
Yes, the unit incorporates shielded (IP65) front BNC connectors. These sockets act as direct and safe taps of the raw AC signal, allowing a portable FFT data collector to be connected without the need to take measurements with the panel energized or open.

Properties

FeatureFunctional Specification
Analog Input Channels12 universal channels
Signal Resolution12 bit
Sampling Rate LimitUp to 250 kHz
Monitoring Formats (HMI)Grid, Plot, Clock, Bar
Display FeaturesTFT Touch 3.5” (89mm) | 480×320 | 24-bit color
Internal Buffer Capacity12 channels x 100 simultaneous samples
Operating Voltage100-240V AC
Alarm Structure12 individual (Threshold and delay adjustment)
Building Envelope ConstructionGRP (Polyester with fiberglass)
Physical dimension of casing350 x 250 x 200 mm
Physical Dimension with Supports395 x 250 x 200 mm
Protocols and Optional HardwareModbus TCP/IP, PC support, Integrated beacon, BNC sockets
Monitran MTN/5000 monitoring system for 12 channels with touch interface and BNC outputs.
Technical diagram of dimensions and connection points of the Monitran MTN/5000 controller.

Other products

Isolator-converter input: 0/1000VDC to Isolated output 0-4/20mA active, Power supply: 24VDC (20.. 30V) isolated.
Monitran-Logo
Top Outlet, Intrinsically Safe ATEX/IECEx | 4-20mA DC Output | RMS Acceleration Measurement | Configurable Range | Frequency 2Hz-1kHz | Power Supply 12-32V DC | Temperature -55 to 90°C | IP67 Protection | Stainless Steel | Mil-C-5015 Connector
Three-phase network analyzer with indication, RS485 + 4/20mA, 3 x /5A input – 3 x 550VAC
3-way isolator: ± 0/10V input, isolated excitation (24V/20mA), isolated output ± 0/10V, isolated 24VDC (20.. 30V) power supply * 2 channels *
Isolated multiplexer of 8 thermocouples to a 4/20mA output (Active / Passive)
3-way galvanic isolator for 0-4/20mA and 0/10V thermocouples. In a narrow 6.2mm case.
4 Pt100 sensor controller with 2 alarms per relay
Comparator of the greater or lesser of 2 – 3 or 4 4/20mA or 0…10 Vdc signals.
4- or 8-cell load cell summing-compensation box with independent sensitivity compensation adjustment. IP65 waterproof enclosure.
Shopping Basket