MTN/5000 Monitoring System
- Manufacturer: Monitran
- Category: Data Logger, INSTRUMENTATION
Data dispersion among multiple isolated sensors on the plant floor critically delays intervention in the event of an abnormal increase in vibration or temperature. Relying solely on manual inspection routes increases the risk of unexpected mechanical failure in continuously rotating equipment.
To centralize the control of these signals, this unit processes and numerically displays readings from up to 12 sensors in real time. Using its touch interface, the operator assigns independent alarm thresholds and delay times for each channel, thus preventing the main relay from malfunctioning in response to natural transient spikes during machine startup.
Its electronics are housed in an insulated glass fiber reinforced polyester (GRP) enclosure, simplifying its structured field installation. By universally accepting 4-20mA analog signals and voltage, it allows for the unified electromechanical status of pumps, fans, and direct drive units at a single point.
- unified management of 12 analog readings.
- Processing to 12 bits with peak speeds of up 250 KHz.
- Visualization in 3.5″ TFT touchscreen (graphs, meter or bars).
- Global electrical power supply range of 100 to 240V AC.
- Temporary storage using 12 x 100 sample buffer.
Technical Frequently Asked Questions
1. Does the system store the behavior prior to an alarm?
Yes. The internal buffer allows the last 100 samples acquired per channel to be retained. This makes it possible to project a trend graph (plot) on the screen to observe the mechanical degradation curve detected before the safety trigger.
2. Can you send your logs to the network installed on the plant?
By integrating the communication module Modbus TCP/IP, The system organically maps the logs of the 12 channels so that they can be read by any centralized SCADA software, allowing remote viewing of the status of the assets.
3. Does it allow for in-depth spectral analysis of the engines?
Yes, the unit incorporates shielded (IP65) front BNC connectors. These sockets act as direct and safe taps of the raw AC signal, allowing a portable FFT data collector to be connected without the need to take measurements with the panel energized or open.
Properties
| Feature | Functional Specification |
|---|---|
| Analog Input Channels | 12 universal channels |
| Signal Resolution | 12 bit |
| Sampling Rate Limit | Up to 250 kHz |
| Monitoring Formats (HMI) | Grid, Plot, Clock, Bar |
| Display Features | TFT Touch 3.5” (89mm) | 480×320 | 24-bit color |
| Internal Buffer Capacity | 12 channels x 100 simultaneous samples |
| Operating Voltage | 100-240V AC |
| Alarm Structure | 12 individual (Threshold and delay adjustment) |
| Building Envelope Construction | GRP (Polyester with fiberglass) |
| Physical dimension of casing | 350 x 250 x 200 mm |
| Physical Dimension with Supports | 395 x 250 x 200 mm |
| Protocols and Optional Hardware | Modbus TCP/IP, PC support, Integrated beacon, BNC sockets |


Other products