{"id":2598,"date":"2025-01-16T03:57:24","date_gmt":"2025-01-16T02:57:24","guid":{"rendered":"https:\/\/guemisa.es\/?post_type=productos&#038;p=2598"},"modified":"2026-10-19T11:47:54","modified_gmt":"2026-10-19T10:47:54","slug":"bc-ph-sentsorea-sz1150","status":"publish","type":"productos","link":"https:\/\/guemisa.es\/eu\/productos\/bc-sensor-de-ph-sz1150\/","title":{"rendered":"SZ1150 pH sentsorea Pt100 integratua duena | B&amp;C Electronics"},"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"guemisa_schema_json":"","subtitulo":"Electrodo industrial de pH con Pt100 integrada, doble uni\u00f3n de PTFE, cuerpo de PVDF y conector de 4 contactos. 0\u201312 pH.","descripcion_del_producto":"<div style=\"font-family: Arial, sans-serif;line-height: 1.65;color: #333333\">\n<p>El <strong>SZ1150 de <a title=\"B&amp;C Electronics: sensores de pH e instrumentaci\u00f3n para an\u00e1lisis de aguas\" href=\"https:\/\/guemisa.es\/marca\/bc-electronics\/\">B&amp;C Electronics<\/a><\/strong> es un <strong>sensor de pH industrial con Pt100 integrada<\/strong>, dise\u00f1ado para medir el pH y la temperatura en el mismo punto del proceso. Utiliza una <strong>membrana de vidrio GX-V<\/strong>, adecuada para medir tambi\u00e9n en medios muy alcalinos, con un <strong>rango de medici\u00f3n de 0 a 14 pH<\/strong>.<\/p>\n<p>La elecci\u00f3n del vidrio GX-V es una de las caracter\u00edsticas que diferencian al SZ1150: est\u00e1 formulado para reducir el <strong>error alcalino<\/strong> que puede aparecer en electrodos de vidrio cuando el pH es elevado. La precisi\u00f3n de la medici\u00f3n depende de las condiciones del proceso, especialmente de la concentraci\u00f3n de sodio y de la temperatura. En aplicaciones con \u00e1lcalis concentrados es importante considerar estas interferencias al seleccionar el electrodo.<\/p>\n<p>El electrodo incorpora un <strong>cuerpo de PVDF<\/strong>, un sistema de referencia de <strong>doble uni\u00f3n de PTFE<\/strong> y electrolito de gel polim\u00e9rico. La Pt100 permite al analizador conocer la temperatura del l\u00edquido y compensar la respuesta t\u00e9rmica del electrodo. Adem\u00e1s, el dise\u00f1o del extremo sensible favorece el arrastre de part\u00edculas mediante el flujo del agua, sin sustituir la limpieza y calibraci\u00f3n peri\u00f3dicas.<\/p>\n<p>Dispone de <strong>rosca de proceso de 3\/4\" NPT<\/strong> para montaje en l\u00ednea o por inmersi\u00f3n mediante accesorios adecuados. Trabaja a temperaturas de <strong>0 a 100 \u00b0C<\/strong> y admite una presi\u00f3n m\u00e1xima de <strong>10 bar a 25 \u00b0C<\/strong>. La conexi\u00f3n el\u00e9ctrica es <strong>DL multipolar de cuatro contactos<\/strong> y utiliza el cable <strong>SZ9441 de 10 metros<\/strong>, suministrado por separado. Se necesita un analizador compatible con electrodos de pH y Pt100; el sensor no proporciona directamente una salida 4\u201320 mA.<\/p>\n<details style=\"display: block;margin: 5px 0 !important;border: 1px solid #b7c4cf;border-left: 4px solid #1F4E78;border-radius: 6px;background-color: #ffffff\">\n<summary style=\"cursor: pointer;padding: 12px 16px;font-size: 18px;font-weight: bold;line-height: 1.4;color: #1f4e78;background-color: #f3f7fa\">Vidrio GX-V: medici\u00f3n hasta pH 14 y error alcalino<\/summary>\n<div style=\"padding: 10px 18px 16px 18px\">\n<h3 style=\"font-size: 20px;color: #333333;margin-top: 10px\">\u00bfQu\u00e9 aporta la membrana GX-V?<\/h3>\n<p>El pH se determina a partir de la diferencia de potencial entre la membrana de vidrio sensible a los iones hidr\u00f3geno y el sistema de referencia. El SZ1150 incorpora una membrana de vidrio <strong>GX-V con geometr\u00eda Semi-Dome<\/strong> y un rango de medici\u00f3n de <strong>0 a 14 pH<\/strong>.<\/p>\n<p>En l\u00edquidos muy alcalinos, los iones de sodio y otros componentes pueden interferir en la respuesta de algunos vidrios de pH. Este fen\u00f3meno, conocido como <strong>error alcalino o error por sodio<\/strong>, puede hacer que el analizador indique un pH inferior al real. El vidrio GX-V est\u00e1 dise\u00f1ado para limitar esa interferencia, por lo que resulta interesante cuando el proceso puede trabajar por encima de pH 12.<\/p>\n<p>En medios con concentraciones elevadas de hidr\u00f3xido s\u00f3dico, el <strong>error alcalino<\/strong> puede influir en la lectura incluso utilizando un vidrio de bajo error alcalino. El rango 0\u201314 pH describe el intervalo de medici\u00f3n del sensor, mientras que la exactitud obtenida depende tambi\u00e9n de la composici\u00f3n y temperatura del l\u00edquido.<\/p>\n<h3 style=\"font-size: 20px;color: #333333;margin-top: 18px\">Sistema electroqu\u00edmico de referencia<\/h3>\n<p>El electrodo utiliza una referencia <strong>Ag\/AgCl (plata\/cloruro de plata)<\/strong>. Este dato describe el sistema electroqu\u00edmico de referencia; la <strong>doble uni\u00f3n de PTFE<\/strong> describe las uniones que lo separan del l\u00edquido de proceso. Son caracter\u00edsticas complementarias, no alternativas.<\/p>\n<\/div>\n<\/details>\n<details style=\"display: block;margin: 5px 0 !important;border: 1px solid #b7c4cf;border-left: 4px solid #1F4E78;border-radius: 6px;background-color: #ffffff\">\n<summary style=\"cursor: pointer;padding: 12px 16px;font-size: 18px;font-weight: bold;line-height: 1.4;color: #1f4e78;background-color: #f3f7fa\">Pt100 integrada y compensaci\u00f3n de temperatura<\/summary>\n<div style=\"padding: 10px 18px 16px 18px\">\n<h3 style=\"font-size: 20px;color: #333333;margin-top: 10px\">\u00bfPor qu\u00e9 medir pH y temperatura juntos?<\/h3>\n<p>La respuesta el\u00e9ctrica de un electrodo de pH cambia con la temperatura. El SZ1150 integra una <strong>Pt100<\/strong> junto al electrodo para que el analizador conozca la temperatura real en el punto donde se realiza la medici\u00f3n.<\/p>\n<p>Una Pt100 es un sensor resistivo de platino cuyo valor nominal es de <strong>100 \u03a9 a 0 \u00b0C<\/strong>. El analizador mide su resistencia, calcula la temperatura y puede utilizarla para aplicar la compensaci\u00f3n t\u00e9rmica a la respuesta del electrodo.<\/p>\n<p>Esto evita tener que instalar una segunda sonda de temperatura junto al sensor de pH y facilita el seguimiento de procesos con cambios t\u00e9rmicos, siempre que el analizador sea compatible.<\/p>\n<p><strong>Conviene distinguir dos efectos:<\/strong> la compensaci\u00f3n corrige la respuesta el\u00e9ctrica del electrodo; no elimina los cambios qu\u00edmicos reales que pueda experimentar el pH del l\u00edquido cuando cambia su temperatura.<\/p>\n<\/div>\n<\/details>\n<details style=\"display: block;margin: 5px 0 !important;border: 1px solid #b7c4cf;border-left: 4px solid #1F4E78;border-radius: 6px;background-color: #ffffff\">\n<summary style=\"cursor: pointer;padding: 12px 16px;font-size: 18px;font-weight: bold;line-height: 1.4;color: #1f4e78;background-color: #f3f7fa\">Conector DL de cuatro contactos y cable SZ9441<\/summary>\n<div style=\"padding: 10px 18px 16px 18px\">\n<h3 style=\"font-size: 20px;color: #333333;margin-top: 10px\">Conexi\u00f3n del electrodo al analizador<\/h3>\n<p>El SZ1150 incorpora un <strong>conector DL multipolar de cuatro contactos<\/strong>. A diferencia de un electrodo que solo entrega se\u00f1al de pH, este modelo necesita transmitir tambi\u00e9n la informaci\u00f3n de la Pt100 integrada.<\/p>\n<p>El cable compatible es el <strong>SZ9441 de B&amp;C Electronics, de 10 metros<\/strong>, y <strong>no est\u00e1 incluido<\/strong> en el suministro del sensor. En el extremo del electrodo utiliza un conector DL hembra de cuatro contactos. El extremo del instrumento se conecta a las entradas de pH y Pt100 conforme al esquema el\u00e9ctrico del cable y del analizador.<\/p>\n<p>Este conector de cuatro contactos no debe confundirse con el <strong>DL coaxial del SZ1140<\/strong>. Los cables SZ947 y SZ9471 de ese modelo no son sustitutos del SZ9441.<\/p>\n<h3 style=\"font-size: 20px;color: #333333;margin-top: 18px\">Transmisor de pH B&amp;C Electronics PH3630<\/h3>\n<p>Para completar el sistema de medici\u00f3n, B&amp;C Electronics ofrece el <strong><a title=\"Transmisor de pH PH3630 B&amp;C Electronics para Pt100 y salida 4\u201320 mA\" href=\"https:\/\/guemisa.es\/productos\/transmisor-ph-ph3630\/\">PH3630<\/a><\/strong>, un transmisor de pH para carril DIN que trabaja en la escala <strong>0\u201314 pH<\/strong> y admite <strong>Pt100 de tres hilos<\/strong>. Dispone de pantalla LCD, compensaci\u00f3n autom\u00e1tica de temperatura y <strong>salida aislada 4\u201320 mA<\/strong> mediante lazo de dos hilos alimentado a 10\u201330 Vcc.<\/p>\n<p>El conjunto se forma conectando el <strong>SZ1150 mediante el cable SZ9441<\/strong> a las entradas de electrodo y Pt100 del PH3630. De esta forma, el transmisor puede mostrar el pH y la temperatura, y enviar la se\u00f1al anal\u00f3gica de pH a un PLC o sistema SCADA. Deben respetarse las conexiones y recomendaciones de instalaci\u00f3n de ambos equipos, especialmente las relativas al aislamiento y longitud del cable.<\/p>\n<h3 style=\"font-size: 20px;color: #333333;margin-top: 18px\">\u00bfSe conecta directamente al PLC?<\/h3>\n<p><strong>No a una entrada convencional de 4\u201320 mA o 0\u201310 V.<\/strong> El SZ1150 es un electrodo electroqu\u00edmico pasivo. Necesita un <strong>analizador de pH con entrada de alta impedancia<\/strong> y compatibilidad con Pt100. Seg\u00fan el analizador elegido, la medida podr\u00e1 despu\u00e9s enviarse a un PLC o SCADA mediante se\u00f1ales anal\u00f3gicas o comunicaciones.<\/p>\n<p>Por la elevada impedancia de la se\u00f1al de pH, deben utilizarse cables adecuados y mantener las conexiones secas, limpias y bien aisladas.<\/p>\n<\/div>\n<\/details>\n<details style=\"display: block;margin: 5px 0 !important;border: 1px solid #b7c4cf;border-left: 4px solid #1F4E78;border-radius: 6px;background-color: #ffffff\">\n<summary style=\"cursor: pointer;padding: 12px 16px;font-size: 18px;font-weight: bold;line-height: 1.4;color: #1f4e78;background-color: #f3f7fa\">Montaje en tuber\u00edas, inmersi\u00f3n y l\u00edmites de funcionamiento<\/summary>\n<div style=\"padding: 10px 18px 16px 18px\">\n<h3 style=\"font-size: 20px;color: #333333;margin-top: 10px\">Dimensiones y conexi\u00f3n de proceso<\/h3>\n<p>El cuerpo incorpora rosca de <strong>3\/4\" NPT<\/strong>, adecuada para montaje en l\u00ednea o para instalaciones por inmersi\u00f3n utilizando el alojamiento o tubo de prolongaci\u00f3n correspondiente.<\/p>\n<p>La <strong>longitud total es de 140 mm<\/strong>, incluyendo el conector superior; la <strong>longitud del cuerpo indicada en el plano es de 120 mm<\/strong>, sin contar ese conector. La longitud de inmersi\u00f3n especificada es de <strong>45 mm<\/strong>.<\/p>\n<h3 style=\"font-size: 20px;color: #333333;margin-top: 18px\">Temperatura, presi\u00f3n y compatibilidad qu\u00edmica<\/h3>\n<p>El rango de temperatura de proceso es de <strong>0 a 100 \u00b0C<\/strong>. La <strong>presi\u00f3n m\u00e1xima es de 10 bar a 25 \u00b0C<\/strong>. El l\u00edmite de temperatura de 100 \u00b0C y el de presi\u00f3n de 10 bar no representan condiciones m\u00e1ximas simult\u00e1neas de funcionamiento.<\/p>\n<p>El PVDF presenta buena resistencia qu\u00edmica frente a numerosos l\u00edquidos, pero debe comprobarse la compatibilidad de todos los materiales mojados con la composici\u00f3n, concentraci\u00f3n y temperatura del proceso.<\/p>\n<p>La zona sensible debe permanecer correctamente humedecida. Conviene evitar bolsas de aire, montajes donde el electrodo pueda quedar seco y posiciones que dificulten la retirada del sensor para calibrarlo.<\/p>\n<\/div>\n<\/details>\n<details style=\"display: block;margin: 5px 0 !important;border: 1px solid #b7c4cf;border-left: 4px solid #1F4E78;border-radius: 6px;background-color: #ffffff\">\n<summary style=\"cursor: pointer;padding: 12px 16px;font-size: 18px;font-weight: bold;line-height: 1.4;color: #1f4e78;background-color: #f3f7fa\">Aplicaciones y selecci\u00f3n para procesos alcalinos<\/summary>\n<div style=\"padding: 10px 18px 16px 18px\">\n<p>El SZ1150 est\u00e1 orientado a la medici\u00f3n continua de pH y temperatura en <strong>tratamiento de aguas, procesos qu\u00edmicos y circuitos industriales<\/strong>. Su rango ampliado permite considerarlo tambi\u00e9n cuando el proceso puede alcanzar valores elevados de pH, siempre que la composici\u00f3n qu\u00edmica sea compatible y el error de medida resulte aceptable.<\/p>\n<ul>\n<li><strong>Tratamiento de aguas:<\/strong> neutralizaci\u00f3n, control de dosificaci\u00f3n y seguimiento del pH con medida de temperatura.<\/li>\n<li><strong>Procesos alcalinos:<\/strong> ba\u00f1os y circuitos donde interesa medir por encima de pH 12 y evaluar el comportamiento del vidrio frente al error alcalino.<\/li>\n<li><strong>Industria qu\u00edmica:<\/strong> monitorizaci\u00f3n de l\u00edquidos de proceso compatibles con el PVDF y el sistema de referencia.<\/li>\n<li><strong>Procesos con temperatura variable:<\/strong> instalaciones en las que resulta \u00fatil obtener pH y temperatura en el mismo punto.<\/li>\n<\/ul>\n<p>En soluciones c\u00e1usticas concentradas conviene definir el tipo de base \u2014por ejemplo, hidr\u00f3xido s\u00f3dico o pot\u00e1sico\u2014, su concentraci\u00f3n, la temperatura y la exactitud requerida antes de seleccionar el electrodo.<\/p>\n<h3 style=\"font-size: 20px;color: #333333;margin-top: 18px\">SZ1150 frente al SZ1140: diferencias t\u00e9cnicas<\/h3>\n<p>Los dos modelos pertenecen a la gama de electrodos industriales de B&amp;C Electronics y comparten cuerpo de PVDF, doble uni\u00f3n de PTFE y montaje roscado de 3\/4\" NPT, pero <strong>no son equivalentes<\/strong>.<\/p>\n<ul>\n<li><strong>SZ1150:<\/strong> membrana de vidrio <strong>GX-V<\/strong>, rango <strong>0\u201314 pH<\/strong>, <strong>Pt100 integrada<\/strong> y conector DL multipolar de cuatro contactos. Utiliza cable SZ9441.<\/li>\n<li><strong><a title=\"Sensor de pH SZ1140 B&amp;C Electronics, rango 0\u201312 pH\" href=\"https:\/\/guemisa.es\/productos\/bc-sensor-de-ph-sz1140\/\">SZ1140<\/a>:<\/strong> rango <strong>0\u201312 pH<\/strong>, sin Pt100 integrada, conexi\u00f3n DL coaxial y cables SZ947 o SZ9471.<\/li>\n<\/ul>\n<p>Por tanto, el SZ1150 ofrece una diferencia funcional doble: un rango de pH m\u00e1s amplio gracias al vidrio GX-V y la posibilidad de medir la temperatura sin instalar una sonda adicional. La elecci\u00f3n final depende de la qu\u00edmica del proceso, el analizador y el tipo de cableado.<\/p>\n<\/div>\n<\/details>\n<details style=\"display: block;margin: 5px 0 !important;border: 1px solid #b7c4cf;border-left: 4px solid #1F4E78;border-radius: 6px;background-color: #ffffff\">\n<summary style=\"cursor: pointer;padding: 12px 16px;font-size: 18px;font-weight: bold;line-height: 1.4;color: #1f4e78;background-color: #f3f7fa\">Doble uni\u00f3n, autolimpieza, calibraci\u00f3n y mantenimiento<\/summary>\n<div style=\"padding: 10px 18px 16px 18px\">\n<h3 style=\"font-size: 20px;color: #333333;margin-top: 10px\">Protecci\u00f3n del sistema de referencia<\/h3>\n<p>La <strong>doble uni\u00f3n de PTFE<\/strong> introduce una barrera adicional entre el l\u00edquido y el sistema de referencia Ag\/AgCl, ayudando a limitar la contaminaci\u00f3n del electrolito. El <strong>gel polim\u00e9rico sellado<\/strong> no necesita rellenado peri\u00f3dico.<\/p>\n<h3 style=\"font-size: 20px;color: #333333;margin-top: 18px\">Efecto de autolimpieza pasiva<\/h3>\n<p>La geometr\u00eda del extremo favorece el paso del l\u00edquido sobre la superficie de medici\u00f3n y el arrastre de part\u00edculas poco adheridas. <strong>No genera turbulencia ni incorpora un mecanismo activo de limpieza.<\/strong> En dep\u00f3sitos estancados o con incrustaciones persistentes seguir\u00e1 siendo necesaria la limpieza manual.<\/p>\n<h3 style=\"font-size: 20px;color: #333333;margin-top: 18px\">Calibraci\u00f3n y conservaci\u00f3n<\/h3>\n<p>El electrodo debe calibrarse peri\u00f3dicamente con soluciones tamp\u00f3n apropiadas al intervalo de trabajo, siguiendo el procedimiento del analizador. Para mediciones muy alcalinas, es especialmente importante comprobar la respuesta en el rango pr\u00f3ximo al pH de proceso.<\/p>\n<p>Para eliminar incrustaciones salinas se indica una limpieza con agua y una soluci\u00f3n de HCl al 3 % durante cinco minutos; para pel\u00edculas de aceite o grasa, agua y detergente. Son operaciones de mantenimiento para personal cualificado, con las medidas de protecci\u00f3n qu\u00edmica correspondientes.<\/p>\n<p>Si la membrana se seca, el procedimiento de acondicionamiento incluye una inmersi\u00f3n inicial de 30 minutos en agua del grifo. Para almacenamiento prolongado debe utilizarse el capuch\u00f3n protector con soluci\u00f3n de conservaci\u00f3n de tamp\u00f3n pH 4 y KCl. La membrana de vidrio debe mantenerse hidratada.<\/p>\n<\/div>\n<\/details>\n<div style=\"margin-top: 16px;padding: 18px 20px;border-left: 4px solid #1F4E78;background-color: #f3f7fa\">\n<h2 style=\"margin: 0 0 10px 0;font-size: 23px;color: #333333\">Selecci\u00f3n del sensor de pH SZ1150 de B&amp;C Electronics<\/h2>\n<p><strong>B&amp;C Electronics<\/strong> es un fabricante italiano especializado en instrumentaci\u00f3n electroqu\u00edmica para an\u00e1lisis de aguas y procesos industriales. En GUEMISA comercializamos sus electrodos y analizadores y ofrecemos asesoramiento para seleccionar el sensor adecuado seg\u00fan el rango de pH, la temperatura, la composici\u00f3n del l\u00edquido y las necesidades de integraci\u00f3n.<\/p>\n<p>Podemos ayudarle a seleccionar el <strong>SZ1150 con vidrio GX-V y Pt100 integrada<\/strong>, su cable SZ9441 y un transmisor compatible como el <strong><a title=\"Transmisor B&amp;C Electronics PH3630\" href=\"https:\/\/guemisa.es\/productos\/transmisor-ph-ph3630\/\">PH3630<\/a><\/strong>, para integrar la medici\u00f3n en un cuadro de control o sistema SCADA.<\/p>\n<p><strong>Cons\u00faltenos para informaci\u00f3n t\u00e9cnica, disponibilidad y presupuesto.<\/strong><\/p>\n<\/div>\n<\/div>\n","propiedades":"<table style=\"width: 100%;border-collapse: collapse;font-family: Arial, sans-serif;margin: 25px 0;border: 1px solid #aab9c5\">\n<thead>\n<tr style=\"background: linear-gradient(90deg, #1F4E78 0%, #7392AC 100%);color: #ffffff;border-bottom: 3px solid #1F4E78\">\n<th style=\"padding: 15px;text-align: left;font-size: 1.25em;color: #ffffff\" colspan=\"2\">ESPECIFICACIONES T\u00c9CNICAS B&amp;C ELECTRONICS SZ1150<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"background: #f3f7fa\">\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Fabricante<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">B&amp;C Electronics<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Modelo<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">SZ1150<\/td>\n<\/tr>\n<tr style=\"background: #f3f7fa\">\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Tipo de electrodo<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">Electrodo combinado de pH con Pt100 integrada<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Membrana de medici\u00f3n<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">Vidrio GX-V Semi-Dome; formulaci\u00f3n de bajo error alcalino<\/td>\n<\/tr>\n<tr style=\"background: #f3f7fa\">\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Rango de medida<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">0\u201314 pH<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Referencia electroqu\u00edmica<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">Ag\/AgCl (plata\/cloruro de plata)<\/td>\n<\/tr>\n<tr style=\"background: #f3f7fa\">\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Sistema de referencia<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">Doble uni\u00f3n de PTFE; electrolito de gel polim\u00e9rico<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Resistencia de membrana<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">&lt;250 M\u03a9<\/td>\n<\/tr>\n<tr style=\"background: #f3f7fa\">\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Temperatura integrada<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">Pt100<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Temperatura de proceso<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">0 a 100 \u00b0C<\/td>\n<\/tr>\n<tr style=\"background: #f3f7fa\">\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Presi\u00f3n m\u00e1xima<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">10 bar a 25 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Material del cuerpo<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">PVDF<\/td>\n<\/tr>\n<tr style=\"background: #f3f7fa\">\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Dise\u00f1o de medici\u00f3n<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">Extremo con efecto de autolimpieza pasiva por circulaci\u00f3n del l\u00edquido<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Conexi\u00f3n de proceso<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">Rosca de 3\/4\" NPT; montaje en l\u00ednea o inmersi\u00f3n<\/td>\n<\/tr>\n<tr style=\"background: #f3f7fa\">\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Conector el\u00e9ctrico<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">DL multipolar de cuatro contactos<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Cable compatible, no incluido<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">SZ9441, 10 metros, conector DL de cuatro contactos<\/td>\n<\/tr>\n<tr style=\"background: #f3f7fa\">\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Longitud total<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">140 mm, incluyendo el conector<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Longitud del cuerpo<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">120 mm, sin incluir el conector<\/td>\n<\/tr>\n<tr style=\"background: #f3f7fa\">\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Longitud de inmersi\u00f3n<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">45 mm<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf;font-weight: bold;color: #1f4e78;width: 40%\">Se\u00f1al del electrodo<\/td>\n<td style=\"padding: 10px;border: 1px solid #b7c4cf\">Se\u00f1al pasiva de pH y resistencia Pt100; requiere analizador compatible<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","referencia":"SZ1150","ficha_tecnica":"https:\/\/guemisa.es\/wp-content\/uploads\/2026\/10\/SZ1150-BC-Electronics-GX-V-pH0-14.pdf","imagen_principal":"2602","dibujo_tecnico":"2599","destacado_portada":"false","rango":"","posicion":"5","rank_math_focus_keyword":"sensor de pH SZ1150 con Pt100","rank_math_title":"Sensor de pH SZ1150 con Pt100 | B&amp;C Electronics","rank_math_description":"Sensor de pH SZ1150 B&amp;C Electronics con Pt100 integrada, doble uni\u00f3n PTFE, PVDF y conector de 4 contactos. Rango 0\u201312 pH, hasta 100 \u00b0C y 10 bar.","schema_json_ld_custom":""},"marca":[76],"industria":[],"categoria":[37,43,119],"class_list":["post-2598","productos","type-productos","status-publish","has-post-thumbnail","hentry","marca-bc-electronics","categoria-sensores","categoria-calidad-del-agua","categoria-ph-y-redox"],"_links":{"self":[{"href":"https:\/\/guemisa.es\/eu\/wp-json\/wp\/v2\/productos\/2598","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/guemisa.es\/eu\/wp-json\/wp\/v2\/productos"}],"about":[{"href":"https:\/\/guemisa.es\/eu\/wp-json\/wp\/v2\/types\/productos"}],"version-history":[{"count":4,"href":"https:\/\/guemisa.es\/eu\/wp-json\/wp\/v2\/productos\/2598\/revisions"}],"predecessor-version":[{"id":10316,"href":"https:\/\/guemisa.es\/eu\/wp-json\/wp\/v2\/productos\/2598\/revisions\/10316"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/guemisa.es\/eu\/wp-json\/wp\/v2\/media\/2602"}],"wp:attachment":[{"href":"https:\/\/guemisa.es\/eu\/wp-json\/wp\/v2\/media?parent=2598"}],"wp:term":[{"taxonomy":"marca","embeddable":true,"href":"https:\/\/guemisa.es\/eu\/wp-json\/wp\/v2\/marca?post=2598"},{"taxonomy":"industria","embeddable":true,"href":"https:\/\/guemisa.es\/eu\/wp-json\/wp\/v2\/industria?post=2598"},{"taxonomy":"categoria","embeddable":true,"href":"https:\/\/guemisa.es\/eu\/wp-json\/wp\/v2\/categoria?post=2598"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}