{"id":73,"count":42,"description":"<div style=\"padding:20px 22px;margin-bottom:14px;border-left:4px solid #e11a29;background:linear-gradient(90deg,rgba(225,26,41,0.09),rgba(225,26,41,0.025)),#f2f2f2;color:#1f1f1f\">\r\n<p style=\"margin-top:0\"><strong>Dimetix AG<\/strong> It is a Swiss manufacturer specializing in the development and manufacture of <strong>High-precision industrial laser distance sensors for non-contact measurement<\/strong>. Its technology allows measuring distance, position, displacement, separation, dimensions, level and movement in applications such as automation, machinery, railways, steelmaking, logistics and structural monitoring.<\/p>\r\n\r\n<p>The <strong>Dimetix D Series<\/strong> It covers different industrial measurement needs: sensors for measuring <strong>up to approximately 50 m over natural surfaces<\/strong>, models capable of achieving <strong>approximately 100 m directly above the object and without a reflector<\/strong>, versions up to <strong>150 m with reflector<\/strong> and long-range industrial sensors capable of measuring <strong>up to 500 m with reflective sheeting<\/strong>.<\/p>\r\n\r\n<p>According to the model, the range offers <strong>Typical accuracies up to \u00b10.5 mm @1\u03c3 \/ \u00b11.0 mm @2\u03c3<\/strong>, measurement frequencies up to <strong>250 Hz<\/strong> and operation from <strong>-40 to +60 \u00b0C<\/strong>.<\/p>\r\n\r\n<div style=\"margin-top:14px;padding-top:13px;border-top:1px solid #cfcfcf\">\r\n<strong>Main ranges of the Dimetix D Series sensors<\/strong>\r\n<ul style=\"margin:7px 0 0 20px\">\r\n<li><strong>Up to ~50 m on natural surfaces:<\/strong> DAE-10-050 and DBN-50-050.<\/li>\r\n<li><strong>Up to ~100 m over natural surfaces, without a reflector:<\/strong> DAN, DEN, DEH and DPE.<\/li>\r\n<li><strong>Up to 150 m with reflector:<\/strong> DAN-10-150 and DAN-30-150.<\/li>\r\n<li><strong>Up to 500 m with reflector:<\/strong> DEN, DEH and DPE.<\/li>\r\n<\/ul>\r\n<\/div>\r\n\r\n<div style=\"margin-top:14px;padding:11px 13px;border-left:3px solid #e11a29\">\r\n<strong>Dimetix is not just a solution for measuring hundreds of meters.<\/strong> The same technological platform is also used in measurements of a few meters and tens of meters when high precision, repeatability and non-contact measurement are needed.\r\n<\/div>\r\n<\/div>\r\n\r\n<div style=\"margin-top: 10px;border: 1px solid #d0d0d0;border-left: 4px solid #e30613;border-radius: 5px;overflow: hidden;background: #ffffff;color: #1f1f1f\"><details style=\"margin: 0;border: 0\"><summary style=\"cursor: pointer;padding: 14px 16px;font-size: 18px;font-weight: bold;color: #1f1f1f;background: linear-gradient(90deg,rgba(227,6,19,0.10),rgba(227,6,19,0.025)),#ededed;border-bottom: 1px solid #d0d0d0\">1. Dimetix D Series Range and Sensor Selection<\/summary>\r\n<div style=\"padding: 16px 18px 20px 18px\">\r\n\r\nThe D Series has different versions to select the sensor according to the <strong>actual working distance, surface type, accuracy, measurement speed, and temperature<\/strong>, avoiding over-provisioning the application.\r\n<h3 style=\"color: #1f1f1f;margin-top: 20px\">Comparison of Dimetix D Series Laser Sensors<\/h3>\r\n<div>\r\n<table style=\"width: 100%;border-collapse: collapse;font-size: 15px\">\r\n<thead>\r\n<tr style=\"background: linear-gradient(90deg,rgba(227,6,19,0.09),rgba(227,6,19,0.02)),#ededed\">\r\n<th style=\"padding: 8px;border: 1px solid #d5d5d5\">Model<\/th>\r\n<th style=\"padding: 8px;border: 1px solid #d5d5d5\">Natural surface<\/th>\r\n<th style=\"padding: 8px;border: 1px solid #d5d5d5\">With reflector<\/th>\r\n<th style=\"padding: 8px;border: 1px solid #d5d5d5\">Accuracy @1\u03c3<\/th>\r\n<th style=\"padding: 8px;border: 1px solid #d5d5d5\">Accuracy @2\u03c3<\/th>\r\n<th style=\"padding: 8px;border: 1px solid #d5d5d5\">Frequency<\/th>\r\n<th style=\"padding: 8px;border: 1px solid #d5d5d5\">Temperature<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\"><strong>DBN-50-050<\/strong><\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">up to ~50 m<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">\u2014<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\"><strong>\u00b12.5 mm<\/strong><\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">\u00b15.0 mm<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">10 Hz<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">-10\u2026+50 \u00b0C<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f7f7f7\">\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\"><strong>DAE-10-050<\/strong><\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">up to ~50 m<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">~40\u202650 m<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\"><strong>\u00b10.5 mm<\/strong><\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">\u00b11.0 mm<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">100 Hz<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">-40\u2026+60 \u00b0C<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\"><strong>DAN-10-150<\/strong><\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">up to ~100 m<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">~40\u2026150 m<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\"><strong>\u00b10.5 mm<\/strong><\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">\u00b11.0 mm<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">100 Hz<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">-10\u2026+50 \u00b0C<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f7f7f7\">\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\"><strong>DAN-30-150<\/strong><\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">up to ~100 m<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">~40\u2026150 m<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\"><strong>\u00b11.5 mm<\/strong><\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">\u00b13.0 mm<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">100 Hz<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">-10\u2026+50 \u00b0C<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\"><strong>DEN-10-500<\/strong><\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">up to ~100 m<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">~0.5\u2026500 m<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\"><strong>\u00b10.5 mm<\/strong><\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">\u00b11.0 mm<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">100 Hz<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">-10\u2026+50 \u00b0C<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f7f7f7\">\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\"><strong>DEH-30-500<\/strong><\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">up to ~100 m<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">~0.5\u2026500 m<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\"><strong>\u00b11.5 mm<\/strong><\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">\u00b13.0 mm<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">100 Hz<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">-10\u2026+60 \u00b0C<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\"><strong>DPE-10-500<\/strong><\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">up to ~100 m<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">~0.5\u2026500 m<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\"><strong>\u00b10.5 mm<\/strong><\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">\u00b11.0 mm<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">250 Hz<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">-40\u2026+60 \u00b0C<\/td>\r\n<\/tr>\r\n<tr style=\"background: #f7f7f7\">\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\"><strong>DPE-30-500<\/strong><\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">up to ~100 m<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">~0.5\u2026500 m<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\"><strong>\u00b11.5 mm<\/strong><\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">\u00b13.0 mm<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">250 Hz<\/td>\r\n<td style=\"padding: 7px;border: 1px solid #e4e4e4\">-40\u2026+60 \u00b0C<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<\/div>\r\n<div style=\"margin-top: 16px;padding: 13px 15px;background: linear-gradient(90deg,rgba(227,6,19,0.07),rgba(227,6,19,0.015)),#f1f1f1;border-left: 3px solid #e30613\">\r\n<p style=\"margin-top: 0\"><strong>How to correctly compare accuracy<\/strong><\/p>\r\nDimetix officially specifies the accuracy of its sensors using a confidence level of <strong>95.4 %, equivalent to 2\u03c3<\/strong>. Other manufacturers may publish their performance at 1\u03c3, approximately 68.3 %. For example, <strong>\u00b10.5 mm @1\u03c3 and \u00b11.0 mm @2\u03c3 represent the same statistical distribution<\/strong>, expressed with different levels of confidence.\r\n<p style=\"margin-bottom: 0\">For transparency, GUEMISA shows <strong>both values<\/strong> to facilitate a homogeneous technical comparison between sensors from different manufacturers.<\/p>\r\n\r\n<\/div>\r\n<h3 style=\"color: #1f1f1f;margin-top: 22px\">Which Dimetix sensor should I choose?<\/h3>\r\n<ul>\r\n \t<li><strong>Up to ~50 my high precision:<\/strong> DAE-10-050 \u2014 \u00b10.5 mm @1\u03c3 \/ \u00b11.0 mm @2\u03c3.<\/li>\r\n \t<li><strong>Up to ~50 m with moderate requirements:<\/strong> DBN-50-050.<\/li>\r\n \t<li><strong>Up to ~100 m without reflector and high precision:<\/strong> DAN-10-150, DEN-10-500 or DPE-10-500.<\/li>\r\n \t<li><strong>Up to 150 m with reflector:<\/strong> DAN-10-150 or DAN-30-150.<\/li>\r\n \t<li><strong>Up to 500 m with reflector:<\/strong> DEN, DEH or DPE.<\/li>\r\n \t<li><strong>Up to 250 Hz:<\/strong> DPE-10-500 and DPE-30-500.<\/li>\r\n \t<li><strong>Operation from -40 \u00b0C:<\/strong> DAE-10-050, DPE-10-500 and DPE-30-500.<\/li>\r\n<\/ul>\r\n<\/div>\r\n<\/details><details style=\"margin: 0;border: 0\"><summary style=\"cursor: pointer;padding: 14px 16px;font-size: 18px;font-weight: bold;color: #1f1f1f;background: linear-gradient(90deg,rgba(227,6,19,0.10),rgba(227,6,19,0.025)),#ededed;border-bottom: 1px solid #d0d0d0\">2. Applications and types of measurement<\/summary>\r\n<div style=\"padding: 16px 18px 20px 18px\">\r\n\r\nDimetix sensors are not limited to measuring absolute distance. One or more laser measurements can be used to determine <strong>position, displacement, separation, width, diameter, length, height, alignment, parallelism, level, and deformation<\/strong>.\r\n<h3 style=\"color: #1f1f1f;margin-top: 20px\">Railway and track geometry<\/h3>\r\nDimetix sensors can be used to perform measurements of <strong>track geometry, track gauge, lane spacing, alignment, leveling, position and parallelism<\/strong>.They can also be integrated into measuring carts and test benches to determine the <strong>position or separation between wheels<\/strong> and other components without mechanical contact.\r\n<h3 style=\"color: #1f1f1f\">Measurement of width, diameter and dimensions<\/h3>\r\nOne or more Dimetix sensors can be used <strong>non-contact dimensional measurements<\/strong>. Two facing sensors allow the calculation of width, diameter, separation, or position when the fixed distance between them is known. This principle can be used to measure coils, rolls, wheels, cylinders, profiles, parts, and other industrial products.\r\n<h3 style=\"color: #1f1f1f\">Iron and steel industry, foundry and metallurgy<\/h3>\r\nDimetix documents applications for <strong>Hot metal level measurement, positioning of transfer carts, coils, diameters, dimensions and steelmaking machinery<\/strong>.Non-contact measurement allows the sensor to be kept away from hot materials and used, when optical conditions are suitable, to measure <strong>level of aluminum, steel and other cast materials<\/strong>.\r\n<h3 style=\"color: #1f1f1f\">Cranes, overhead cranes and stacker cranes<\/h3>\r\nDimetix sensors can continuously determine the <strong>position of cranes, overhead cranes, trolleys, stacker cranes and other mobile mechanisms<\/strong>.The measurements can be used for positioning, path control, synchronization, and motion monitoring.\r\n<h3 style=\"color: #1f1f1f\">Level measurement<\/h3>\r\nThe distance to the surface of a material allows us to determine the <strong>level in silos, hoppers, tanks, solids and raw materials<\/strong> without direct contact with the product.\r\n<h3 style=\"color: #1f1f1f\">Civil works and structural monitoring<\/h3>\r\nRemote measurement allows for control <strong>displacements, movements and changes in position in bridges, tunnels, pillars, buildings, slopes and other structures<\/strong>.\r\n\r\n<\/div>\r\n<\/details><details style=\"margin: 0;border: 0\"><summary style=\"cursor: pointer;padding: 14px 16px;font-size: 18px;font-weight: bold;color: #1f1f1f;background: linear-gradient(90deg,rgba(227,6,19,0.10),rgba(227,6,19,0.025)),#ededed;border-bottom: 1px solid #d0d0d0\">3. Technical installation guide and frequently asked questions<\/summary>\r\n<div style=\"padding: 8px 18px 16px 18px\"><details style=\"margin: 0;border-bottom: 1px solid #dddddd\"><summary style=\"cursor: pointer;padding: 11px 2px;font-weight: bold;color: #1f1f1f\">How to correctly install a reflective plate or sheet?<\/summary>\r\n<div style=\"padding: 0 8px 12px 8px\">\r\n\r\nDimetix recommends using a suitable reflector for the sensor and mounting it with a <strong>slight inclination with respect to the perpendicular of the beam<\/strong> To avoid excessively direct reflection towards the receiving optics, the entire laser spot must remain within the reflective surface throughout the application path. The reflector must be kept clean and undamaged.\r\n\r\n<\/div>\r\n<\/details><details style=\"margin: 0;border-bottom: 1px solid #dddddd\"><summary style=\"cursor: pointer;padding: 11px 2px;font-weight: bold;color: #1f1f1f\">Can it be measured through glass?<\/summary>\r\n<div style=\"padding: 0 8px 12px 8px\">\r\n\r\nDimetix recommends avoiding measurements through glass whenever possible, as reflections and optical losses can affect the measurement. When using a window is necessary, it is recommended <strong>anti-reflective coated glass<\/strong>, Keep it clean and install it at an approximate angle of <strong>5th or higher<\/strong> regarding the front of the sensor.\r\n\r\n<\/div>\r\n<\/details><details style=\"margin: 0;border-bottom: 1px solid #dddddd\"><summary style=\"cursor: pointer;padding: 11px 2px;font-weight: bold;color: #1f1f1f\">Can a mirror be used to deflect the laser beam?<\/summary>\r\n<div style=\"padding: 0 8px 12px 8px\">\r\n\r\nIt should be avoided when the installation allows for a direct path. If it is necessary to modify the optical path, Dimetix recommends using a <strong>mirror suitable for optical applications<\/strong>, The mirror should be sufficiently large and correctly oriented. It should be kept clean, and the plausibility of the measurements obtained during operation should be checked.\r\n\r\n<\/div>\r\n<\/details><details style=\"margin: 0;border-bottom: 1px solid #dddddd\"><summary style=\"cursor: pointer;padding: 11px 2px;font-weight: bold;color: #1f1f1f\">Can it be measured directly on a very shiny or mirror-like surface?<\/summary>\r\n<div style=\"padding: 0 8px 12px 8px\">\r\n\r\nHighly reflective surfaces should be avoided. Excessive reflection can cause measurement fluctuations or errors. When a shiny surface cannot be avoided, the angle of incidence should be adjusted and the actual application behavior checked.\r\n\r\n<\/div>\r\n<\/details><details style=\"margin: 0;border-bottom: 1px solid #dddddd\"><summary style=\"cursor: pointer;padding: 11px 2px;font-weight: bold;color: #1f1f1f\">How do rough or irregular surfaces affect things?<\/summary>\r\n<div style=\"padding: 0 8px 12px 8px\">\r\n\r\nWhen a surface is rough, different areas of the laser spot may be at different distances. The geometry and roughness of the object must be taken into account when interpreting the measurement.\r\n\r\n<\/div>\r\n<\/details><details style=\"margin: 0;border-bottom: 1px solid #dddddd\"><summary style=\"cursor: pointer;padding: 11px 2px;font-weight: bold;color: #1f1f1f\">What about wood, plastic, or semi-transparent materials?<\/summary>\r\n<div style=\"padding: 0 8px 12px 8px\">\r\n\r\nIn certain porous or partially translucent materials, some light may penetrate slightly, so the measurement may differ from the exact position on the outer surface. For precision applications, it is advisable to validate the behavior on the specific material beforehand.\r\n\r\n<\/div>\r\n<\/details><details style=\"margin: 0;border-bottom: 1px solid #dddddd\"><summary style=\"cursor: pointer;padding: 11px 2px;font-weight: bold;color: #1f1f1f\">Can Dimetix measure moving objects?<\/summary>\r\n<div style=\"padding: 0 8px 12px 8px\">\r\n\r\nYes. The capacity depends on the target speed, the surface, and the selected measurement frequency. The models <strong>DPE-10-500 and DPE-30-500 reach up to 250 Hz<\/strong>, allowing work on dynamic applications where a high refresh rate is needed.\r\n\r\n<\/div>\r\n<\/details><details style=\"margin: 0;border-bottom: 1px solid #dddddd\"><summary style=\"cursor: pointer;padding: 11px 2px;font-weight: bold;color: #1f1f1f\">How does sunlight affect the measurement?<\/summary>\r\n<div style=\"padding: 0 8px 12px 8px\">\r\n\r\nIntense ambient light can reduce the quality of the optical signal and the maximum achievable performance. In outdoor applications, visors, covers, or other mechanical devices can be used to reduce direct light exposure. The sensor should not be pointed directly at the sun.\r\n\r\n<\/div>\r\n<\/details><details style=\"margin: 0;border-bottom: 1px solid #dddddd\"><summary style=\"cursor: pointer;padding: 11px 2px;font-weight: bold;color: #1f1f1f\">Can a Dimetix sensor be used outdoors?<\/summary>\r\n<div style=\"padding: 0 8px 12px 8px\">\r\n\r\nThe D Series has protection <strong>IP65<\/strong>. In permanent outdoor installations, it is advisable to protect the optics from rain, snow, dirt, and water accumulation. The DAE and DPE models also allow operation from <strong>-40 to +60 \u00b0C<\/strong>.\r\n\r\n<\/div>\r\n<\/details><details style=\"margin: 0;border-bottom: 1px solid #dddddd\"><summary style=\"cursor: pointer;padding: 11px 2px;font-weight: bold;color: #1f1f1f\">How does dust affect a laser sensor?<\/summary>\r\n<div style=\"padding: 0 8px 12px 8px\">\r\n\r\nSmall amounts of dust may not impede the measurement, but high concentrations of suspended particles can reflect part of the beam and reduce the measurement quality. In very dusty environments, it may be necessary to protect the optics or keep them clean with a suitable solution.\r\n\r\n<\/div>\r\n<\/details><details style=\"margin: 0;border-bottom: 1px solid #dddddd\"><summary style=\"cursor: pointer;padding: 11px 2px;font-weight: bold;color: #1f1f1f\">What do 1\u03c3 and 2\u03c3 mean in Dimetix accuracy?<\/summary>\r\n<div style=\"padding: 0 8px 12px 8px\">\r\n\r\n<strong>1\u03c3<\/strong> represents approximately 68.3 % of the measurements within the indicated range, while <strong>2\u03c3<\/strong> This corresponds to approximately 95.4 %. Therefore, <strong>\u00b10.5 mm @1\u03c3 and \u00b11.0 mm @2\u03c3<\/strong> They can describe the same statistical distribution. It is important to verify this criterion when comparing sensors from different manufacturers.\r\n\r\n<\/div>\r\n<\/details><details style=\"margin: 0\"><summary style=\"cursor: pointer;padding: 11px 2px;font-weight: bold;color: #1f1f1f\">How do you align a Dimetix sensor over a long distance?<\/summary>\r\n<div style=\"padding: 0 8px 12px 8px\">\r\n\r\nThe greater the distance, the more important the sensor&#039;s angular alignment becomes. Small orientation errors can produce significant shifts in the laser spot on the target. Dimetix offers a <strong>alignment unit for the D Series<\/strong> which allows the sensor to be adjusted on two axes. In long-travel applications, it must be ensured that the laser dot remains within the target or reflector throughout the intended movement.\r\n\r\n<\/div>\r\n<\/details><\/div>\r\n<\/details><details style=\"margin: 0;border: 0\"><summary style=\"cursor: pointer;padding: 14px 16px;font-size: 18px;font-weight: bold;color: #1f1f1f;background: linear-gradient(90deg,rgba(227,6,19,0.10),rgba(227,6,19,0.025)),#ededed\">4. Interfaces, configuration and integration<\/summary>\r\n<div style=\"padding: 16px 18px 20px 18px\">\r\n<h3 style=\"color: #1f1f1f;margin-top: 0\">Industrial interfaces<\/h3>\r\nAccording to the model, the D Series can have different interfaces for integration into PLCs, data acquisition systems and industrial automation.\r\n<ul>\r\n \t<li>RS-232.<\/li>\r\n \t<li>RS-422.<\/li>\r\n \t<li>SSI according to model.<\/li>\r\n \t<li>Programmable analog output 0\/4-20 mA depending on the model.<\/li>\r\n \t<li>Digital inputs and outputs.<\/li>\r\n \t<li><strong>PROFINET<\/strong> via industrial interface for D Series.<\/li>\r\n \t<li><strong>EtherNet\/IP<\/strong> via industrial interface for D Series.<\/li>\r\n \t<li><strong>EtherCAT<\/strong> via industrial interface for D Series.<\/li>\r\n<\/ul>\r\n<h3 style=\"color: #1f1f1f\">Configuration<\/h3>\r\nDimetix software tools allow you to configure sensor parameters, check measurements, and save configurations for use on other compatible equipment.\r\n<h3 style=\"color: #1f1f1f\">Maintenance and calibration<\/h3>\r\nThe D Series requires minimal maintenance, but the optics must be kept clean to prevent signal loss or errors. Dimetix also offers calibration and recalibration services for its sensors.\r\n<h3 style=\"color: #1f1f1f\">OEM Integration<\/h3>\r\nDimetix also works with manufacturers and integrators who need to incorporate laser measurement technology into machinery, their own equipment, and OEM solutions.\r\n\r\n<\/div>\r\n<\/details><\/div>\r\n<div style=\"margin-top: 14px;padding: 14px 18px;border-left: 4px solid #e30613;background: linear-gradient(90deg,rgba(227,6,19,0.07),rgba(227,6,19,0.015)),#f1f1f1;color: #1f1f1f\"><strong>Do you need to select a Dimetix sensor?<\/strong>\r\nGUEMISA offers technical support to define the appropriate model, range, accuracy, reflector, interfaces, and accessories for each application.<\/div>","link":"https:\/\/guemisa.es\/en\/marca\/dimetix\/","name":"DIMETIX AG","slug":"dimetix","taxonomy":"marca","meta":[],"_links":{"self":[{"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/marca\/73","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/marca"}],"about":[{"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/taxonomies\/marca"}],"wp:post_type":[{"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/productos?marca=73"},{"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/documentos-pdf?marca=73"},{"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/casos-de-uso?marca=73"},{"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/archivos?marca=73"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}