{"id":90,"count":49,"description":"<h3 data-section-id=\"p10gq5\" data-start=\"1809\" data-end=\"1850\">4-20 mA Process and Signal Isolators<\/h3>\r\n<p data-start=\"1852\" data-end=\"2204\">The <strong data-start=\"1856\" data-end=\"1881\">process isolators<\/strong> They are electronic devices used in industrial automation systems to provide <strong data-start=\"1982\" data-end=\"2032\">galvanic isolation between analog signals<\/strong>. Its main function is to protect control equipment, PLCs and data acquisition systems against electrical interference, ground loops and potential differences.<\/p>\r\n<p data-start=\"2206\" data-end=\"2430\">In industrial applications it is common to use <strong data-start=\"2256\" data-end=\"2296\">signal isolators 4-20 mA or 0-10 V<\/strong>, especially when signals from sensors need to be reliably transmitted to control or monitoring systems.<\/p>\r\n<p data-start=\"2432\" data-end=\"2608\">The use of <strong data-start=\"2442\" data-end=\"2467\">galvanic insulators<\/strong> It allows for improved measurement stability, reduced electrical noise, and protection of equipment against overvoltages or ground faults.<\/p>\r\n\r\n\r\n<hr data-start=\"2610\" data-end=\"2613\" \/>\r\n\r\n<h3 data-section-id=\"15514t1\" data-start=\"2615\" data-end=\"2642\">Common applications<\/h3>\r\n<p data-start=\"2644\" data-end=\"2715\">Signal isolators are used in numerous industrial sectors:<\/p>\r\n\r\n<ul data-start=\"2717\" data-end=\"2878\">\r\n \t<li data-section-id=\"rgam4d\" data-start=\"2717\" data-end=\"2744\">\r\n<p data-start=\"2719\" data-end=\"2744\">industrial automation<\/p>\r\n<\/li>\r\n \t<li data-section-id=\"187wt5p\" data-start=\"2745\" data-end=\"2773\">\r\n<p data-start=\"2747\" data-end=\"2773\">process instrumentation<\/p>\r\n<\/li>\r\n \t<li data-section-id=\"12pg6my\" data-start=\"2774\" data-end=\"2797\">\r\n<p data-start=\"2776\" data-end=\"2797\">machinery control<\/p>\r\n<\/li>\r\n \t<li data-section-id=\"1vdfun5\" data-start=\"2798\" data-end=\"2816\">\r\n<p data-start=\"2800\" data-end=\"2816\">chemical plants<\/p>\r\n<\/li>\r\n \t<li data-section-id=\"jtj4vx\" data-start=\"2817\" data-end=\"2838\">\r\n<p data-start=\"2819\" data-end=\"2838\">water treatment<\/p>\r\n<\/li>\r\n \t<li data-section-id=\"9n8aa6\" data-start=\"2839\" data-end=\"2861\">\r\n<p data-start=\"2841\" data-end=\"2861\">energy industry<\/p>\r\n<\/li>\r\n \t<li data-section-id=\"l82bp7\" data-start=\"2862\" data-end=\"2878\">\r\n<p data-start=\"2864\" data-end=\"2878\">SCADA systems<\/p>\r\n<\/li>\r\n<\/ul>\r\n\r\n<hr data-start=\"2880\" data-end=\"2883\" \/>\r\n\r\n<h3 data-section-id=\"1y7gj0k\" data-start=\"2885\" data-end=\"2917\">Types of signal isolators<\/h3>\r\n<p data-start=\"2919\" data-end=\"2994\">In this category you will find different types of <strong data-start=\"2968\" data-end=\"2993\">process isolators<\/strong>:<\/p>\r\n\r\n<ul data-start=\"2996\" data-end=\"3163\">\r\n \t<li data-section-id=\"1n62skt\" data-start=\"2996\" data-end=\"3029\">\r\n<p data-start=\"2998\" data-end=\"3029\"><strong data-start=\"2998\" data-end=\"3029\">4-20 mA signal isolators<\/strong><\/p>\r\n<\/li>\r\n \t<li data-section-id=\"12c6x3v\" data-start=\"3030\" data-end=\"3053\">\r\n<p data-start=\"3032\" data-end=\"3053\"><strong data-start=\"3032\" data-end=\"3053\">0-10 V insulators<\/strong><\/p>\r\n<\/li>\r\n \t<li data-section-id=\"1m05q3u\" data-start=\"3054\" data-end=\"3081\">\r\n<p data-start=\"3056\" data-end=\"3081\"><strong data-start=\"3056\" data-end=\"3081\">signal doublers<\/strong><\/p>\r\n<\/li>\r\n \t<li data-section-id=\"h7uifj\" data-start=\"3082\" data-end=\"3113\">\r\n<p data-start=\"3084\" data-end=\"3113\"><strong data-start=\"3084\" data-end=\"3113\">signal quadruplers<\/strong><\/p>\r\n<\/li>\r\n \t<li data-section-id=\"ix767f\" data-start=\"3114\" data-end=\"3163\">\r\n<p data-start=\"3116\" data-end=\"3163\"><strong data-start=\"3116\" data-end=\"3163\">universal insulators for instrumentation<\/strong><\/p>\r\n<\/li>\r\n<\/ul>\r\n<p data-start=\"3165\" data-end=\"3264\">These devices allow you to split, convert, or isolate analog signals from sensors such as:<\/p>\r\n\r\n<ul data-start=\"3266\" data-end=\"3370\">\r\n \t<li data-section-id=\"14mq78p\" data-start=\"3266\" data-end=\"3287\">\r\n<p data-start=\"3268\" data-end=\"3287\">pressure sensors<\/p>\r\n<\/li>\r\n \t<li data-section-id=\"1v0jdq9\" data-start=\"3288\" data-end=\"3313\">\r\n<p data-start=\"3290\" data-end=\"3313\">temperature sensors<\/p>\r\n<\/li>\r\n \t<li data-section-id=\"rubwha\" data-start=\"3314\" data-end=\"3342\">\r\n<p data-start=\"3316\" data-end=\"3342\">industrial transducers<\/p>\r\n<\/li>\r\n \t<li data-section-id=\"dt3f4s\" data-start=\"3343\" data-end=\"3370\">\r\n<p data-start=\"3345\" data-end=\"3370\">PLC process signals<\/p>\r\n<\/li>\r\n<\/ul>\r\n\r\n<hr data-start=\"3372\" data-end=\"3375\" \/>\r\n\r\n<h3 data-section-id=\"30tzzj\" data-start=\"3377\" data-end=\"3415\">Advantages of galvanic isolation<\/h3>\r\n<p data-start=\"3417\" data-end=\"3479\">The use of signal isolators offers several technical advantages:<\/p>\r\n\r\n<ul data-start=\"3481\" data-end=\"3665\">\r\n \t<li data-section-id=\"h6n1g\" data-start=\"3481\" data-end=\"3512\">\r\n<p data-start=\"3483\" data-end=\"3512\">elimination of mass loops<\/p>\r\n<\/li>\r\n \t<li data-section-id=\"zdqok2\" data-start=\"3513\" data-end=\"3544\">\r\n<p data-start=\"3515\" data-end=\"3544\">reduction of electrical noise<\/p>\r\n<\/li>\r\n \t<li data-section-id=\"tkybmr\" data-start=\"3545\" data-end=\"3579\">\r\n<p data-start=\"3547\" data-end=\"3579\">protection of control equipment<\/p>\r\n<\/li>\r\n \t<li data-section-id=\"la8ak5\" data-start=\"3580\" data-end=\"3621\">\r\n<p data-start=\"3582\" data-end=\"3621\">improved signal stability<\/p>\r\n<\/li>\r\n \t<li data-section-id=\"1pwz0cc\" data-start=\"3622\" data-end=\"3665\">\r\n<p data-start=\"3624\" data-end=\"3665\">greater reliability in industrial systems<\/p>\r\n<\/li>\r\n<\/ul>\r\n\r\n<hr data-start=\"3667\" data-end=\"3670\" \/>\r\n\r\n<h1 data-section-id=\"1sv4wck\" data-start=\"3672\" data-end=\"3710\">7\ufe0f\u20e3 Add FAQs (this improves ranking A LOT)<\/h1>\r\n<p data-start=\"3711\" data-end=\"3747\">Add this to the end of the category.<\/p>\r\n\r\n<h3 data-section-id=\"aqfdat\" data-start=\"3749\" data-end=\"3790\">What is a 4-20 mA signal isolator?<\/h3>\r\n<p data-start=\"3792\" data-end=\"3989\">A 4-20 mA signal isolator is an electronic device that allows the transmission of an analog signal while maintaining galvanic isolation between input and output to avoid electrical interference.<\/p>\r\n\r\n\r\n<hr data-start=\"3991\" data-end=\"3994\" \/>\r\n\r\n<h3 data-section-id=\"1dhsxw0\" data-start=\"3996\" data-end=\"4038\">What is a galvanic insulator used for?<\/h3>\r\n<p data-start=\"4040\" data-end=\"4222\">Galvanic isolators are used to protect electronic equipment against potential differences, ground loops, and electrical noise in industrial automation systems.<\/p>\r\n\r\n\r\n<hr data-start=\"4224\" data-end=\"4227\" \/>\r\n\r\n<h3 data-section-id=\"1s1sfq7\" data-start=\"4229\" data-end=\"4274\">When is a signal isolator needed?<\/h3>\r\n<p data-start=\"4276\" data-end=\"4322\">Signal isolators are recommended when:<\/p>\r\n\r\n<ul data-start=\"4324\" data-end=\"4480\">\r\n \t<li data-section-id=\"9i7kht\" data-start=\"4324\" data-end=\"4348\">\r\n<p data-start=\"4326\" data-end=\"4348\">mass loops exist<\/p>\r\n<\/li>\r\n \t<li data-section-id=\"rb3f7x\" data-start=\"4349\" data-end=\"4389\">\r\n<p data-start=\"4351\" data-end=\"4389\">The signals travel long distances<\/p>\r\n<\/li>\r\n \t<li data-section-id=\"1nuwcjn\" data-start=\"4390\" data-end=\"4421\">\r\n<p data-start=\"4392\" data-end=\"4421\">There is electrical interference<\/p>\r\n<\/li>\r\n \t<li data-section-id=\"1m5lxcv\" data-start=\"4422\" data-end=\"4480\">\r\n<p data-start=\"4424\" data-end=\"4480\">Equipment with different ground references is connected<\/p>\r\n<\/li>\r\n<\/ul>","link":"https:\/\/guemisa.es\/en\/categoria\/aisladores-proceso\/","name":"Process isolators","slug":"process-insulators","taxonomy":"categoria","parent":89,"meta":[],"_links":{"self":[{"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/categoria\/90","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/categoria"}],"about":[{"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/taxonomies\/categoria"}],"up":[{"embeddable":true,"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/categoria\/89"}],"wp:post_type":[{"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/productos?categoria=90"},{"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/documentos-pdf?categoria=90"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}