{"id":7468,"date":"2026-08-06T11:01:21","date_gmt":"2026-08-06T10:01:21","guid":{"rendered":"https:\/\/guemisa.es\/?post_type=casos-de-uso&#038;p=7468"},"modified":"2026-08-06T11:43:58","modified_gmt":"2026-08-06T10:43:58","slug":"dimetix-dls-c-15-replacement-by-dpe-10-500","status":"publish","type":"casos-de-uso","link":"https:\/\/guemisa.es\/en\/casos-de-uso\/dimetix-dls-c-15-sustitucion-por-dpe-10-500\/","title":{"rendered":"Dimetix DLS-C 15: replacement by DPE-10-500"},"content":{"rendered":"<article class=\"caso-de-uso-dimetix\">\n<header>\n<h2>Compatibility between Dimetix DLS-C 15 and DPE-10-500 in an existing installation<\/h2>\n<p>\n            Replacing a discontinued industrial sensor can become a problem<br \/>\n            when the equipment is part of an installation developed years ago. In addition to the<br \/>\n            Metrological performance, the communication protocol, the commands must be preserved<br \/>\n            used by the software and compatibility with existing control systems.\n        <\/p>\n<p>\n            In this case we are analyzing the replacement of the old laser sensor<br \/>\n            <strong>Dimetix DLS-C 15<\/strong> by the current<br \/>\n            <strong>Dimetrix DPE-10-500<\/strong> in a museum facility located in Catalonia,<br \/>\n            equipped with 16 distance sensors.\n        <\/p>\n<p>        <br \/>\n        <img fetchpriority=\"high\" decoding=\"async\"\n            class=\"wp-image-7472 size-full\"\n            src=\"https:\/\/guemisa.es\/wp-content\/uploads\/2026\/08\/DLS-C-15-comparativa-dimetix-dpe-10-500-2.png\"\n            alt=\"Comparison between the discontinued Dimetix DLS-C 15 laser sensor and the current DPE-10-500 model\"\n            width=\"1503\"\n            height=\"1046\"\n        \/><br \/>\n        Comparison between the old Dimetix DLS-C 15 laser sensor and the current one<br \/>\n        DPE-10-500, tested as an alternative to modernize an existing installation.<br \/>\n        <br \/>\n    <\/header>\n<section>\n<h2>Key data of the use case<\/h2>\n<ul>\n<li>\n                <strong>Manufacturer:<\/strong><br \/>\n                <a href=\"https:\/\/guemisa.es\/en\/brand\/dimethix\/\">Dimetix AG<\/a>\n            <\/li>\n<li><strong>Sector:<\/strong> Museums and technical facilities<\/li>\n<li><strong>Location:<\/strong> Catalonia<\/li>\n<li>\n                <strong>Application:<\/strong><br \/>\n                <a href=\"https:\/\/guemisa.es\/en\/category\/laser-distance-sensor\/\"><br \/>\n                    Non-contact laser distance measurement<br \/>\n                <\/a>\n            <\/li>\n<li><strong>Installed model:<\/strong> Dimetix DLS-C 15<\/li>\n<li><strong>Tested model:<\/strong> Dimetrix DPE-10-500<\/li>\n<li><strong>Number of existing sensors:<\/strong> 16 units<\/li>\n<li><strong>Operating system used:<\/strong> Windows 7<\/li>\n<li><strong>Interfaces analyzed:<\/strong> USB, RS-232 and RS-422<\/li>\n<\/ul>\n<\/section>\n<section>\n<h2>The problem: replacing a discontinued Dimetix DLS-C 15<\/h2>\n<p>\n            The analyzed installation has 16 sensors<br \/>\n            <strong>Dimetix DLS-C 15<\/strong> which have been operating within their<br \/>\n            measurement system. However, this model belongs to a previous generation.<br \/>\n            from Dimetix sensors and is currently discontinued.\n        <\/p>\n<p>\n            The main risk to the installation was not the functioning of the sensors<br \/>\n            existing, but the difficulty in finding an equivalent unit in case of breakdown.<br \/>\n            The introduction of a new generation could require modifications to the software, the<br \/>\n            connection, serial communication or even part of the acquisition system.\n        <\/p>\n<p>Before considering a replacement, it was necessary to answer several questions:<\/p>\n<ul>\n<li>Can the new sensor communicate with the existing computer?<\/li>\n<li>Is it possible to use it with the operating system already installed?<\/li>\n<li>Are the commands used by the old DLS-C 15 still supported?<\/li>\n<li>Are RS-232 and RS-422 communications compatible?<\/li>\n<li>Can the core logic of the acquisition software be preserved?<\/li>\n<li>Are the features improved compared to the old model?<\/li>\n<\/ul>\n<\/section>\n<section>\n<h2>Features of the old Dimetix DLS-C 15<\/h2>\n<p>\n            He <strong>Dimetix DLS-C 15<\/strong> It is an industrial sensor designed to measure<br \/>\n            non-contact distances using a visible laser beam.\n        <\/p>\n<p>Its main features include:<\/p>\n<ul>\n<li>Typical accuracy of \u00b11.5 mm.<\/li>\n<li>Typical repeatability of \u00b10.4 mm.<\/li>\n<li>Maximum measurement frequency up to 6 Hz.<\/li>\n<li>Approximate range of 65 m over natural surfaces.<\/li>\n<li>Range up to 150 m using a reflective plate.<\/li>\n<li>Communication via RS-232 and RS-422.<\/li>\n<li>Configurable analog output of 0\u202620 mA or 4\u202620 mA.<\/li>\n<li>Programmable digital inputs and outputs.<\/li>\n<li>ASCII command-based communication protocol.<\/li>\n<\/ul>\n<p>\n            These features led to the DLS series being used for years in various applications<br \/>\n            industrial positioning, dimensional control, level and automatic acquisition<br \/>\n            of distances.\n        <\/p>\n<\/section>\n<section>\n<h2>Testing the Dimetix DPE-10-500 in the existing installation<\/h2>\n<p>\n            To verify the feasibility of the replacement, a test was carried out directly on<br \/>\n            the museum installation, along with its technical team.\n        <\/p>\n<p>\n            The selected sensor was the <strong>Dimetrix DPE-10-500<\/strong>, one of the models<br \/>\n            current D-series. This sensor offers typical accuracy of \u00b11 mm and a<br \/>\n            range of up to 500 m when using a suitable reflective surface.\n        <\/p>\n<p>\n            The computer used for the installation was running on <strong>Windows 7<\/strong>.<br \/>\n            The USB drivers corresponding to the new D series were installed and connected<br \/>\n            The DPE-10-500 connects directly to the computer via a USB cable.\n        <\/p>\n<p>\n            After installing the driver, the system recognized the sensor as a<br \/>\n            <strong>virtual serial port COM<\/strong>. Communication was successfully established<br \/>\n            On the first attempt, it was possible to receive the distance measurements without modifying the<br \/>\n            Main logic used to communicate with the above sensors.\n        <\/p>\n<p>\n            Compatibility with Windows 7 was practically confirmed on the computer used<br \/>\n            during the test. This result corresponds to the specific equipment and configuration.<br \/>\n            of the installation and should not be interpreted as a general certification for any<br \/>\n            computer equipped with this operating system.\n        <\/p>\n<aside>\n<p>\n                <strong>Test result:<\/strong> the DPE-10-500 worked correctly from<br \/>\n                The first connection via USB was recognized as a COM port and transmitted the<br \/>\n                expected distance values.\n            <\/p>\n<\/aside>\n<\/section>\n<section>\n<h2>Protocol compatibility between the old DLS series and the D series<\/h2>\n<p>\n            One of the most important results of the validation was verifying that the new<br \/>\n            DPE-10-500 maintains the communication protocol used by the DLS-C 15 for the<br \/>\n            main measurement functions.\n        <\/p>\n<p>\n            Both the old DLS series and the current D series use a<br \/>\n            <strong>ASCII command protocol<\/strong>. The instructions are sent via a<br \/>\n            serial interface and responses include the sensor identifier, measurement type<br \/>\n            and the distance value.\n        <\/p>\n<p>\n            In the current D series, this protocol can be used via RS-232 interfaces,<br \/>\n            RS-422\/485 and USB. The USB connection behaves like a virtual COM port, allowing<br \/>\n            that the software treats the sensor as a conventional serial device.\n        <\/p>\n<p>\n            Commands are completed using carriage return and line feed characters.,<br \/>\n            known as <code>CR<\/code> and <code>LF<\/code>.\n        <\/p>\n<h3>Main supported commands<\/h3>\n<div class=\"table-responsive\" style=\"overflow-x:auto;\">\n<table>\n<thead>\n<tr>\n<th>Command<\/th>\n<th>Function<\/th>\n<th>DLS-C 15<\/th>\n<th>DPE-10-500<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><code>sNg<\/code><\/td>\n<td>Take an individual distance measurement<\/td>\n<td>Yeah<\/td>\n<td>Yeah<\/td>\n<\/tr>\n<tr>\n<td><code>sNh<\/code><\/td>\n<td>Start continuous measurement<\/td>\n<td>Yeah<\/td>\n<td>Yeah<\/td>\n<\/tr>\n<tr>\n<td><code>sNf<\/code><\/td>\n<td>Start continuous measurement with buffer storage<\/td>\n<td>Yeah<\/td>\n<td>Yeah<\/td>\n<\/tr>\n<tr>\n<td><code>sNq<\/code><\/td>\n<td>Read the last stored measurement<\/td>\n<td>Yeah<\/td>\n<td>Yeah<\/td>\n<\/tr>\n<tr>\n<td><code>sNc<\/code><\/td>\n<td>Stop or cancel active measurement<\/td>\n<td>Yeah<\/td>\n<td>Yeah<\/td>\n<\/tr>\n<tr>\n<td><code>sNm<\/code><\/td>\n<td>Check the strength of the received signal<\/td>\n<td>Yeah<\/td>\n<td>Yeah<\/td>\n<\/tr>\n<tr>\n<td><code>sNt<\/code><\/td>\n<td>Check the internal temperature of the sensor<\/td>\n<td>Yeah<\/td>\n<td>Yeah<\/td>\n<\/tr>\n<tr>\n<td><code>sNo<\/code><\/td>\n<td>\n                            Temporarily activate the laser to facilitate alignment;<br \/>\n                            it stops by <code>sNc<\/code>\n                        <\/td>\n<td>Yeah<\/td>\n<td>Yeah<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>\n            For example, the command <code>sNg<\/code> activates an individual measure in both<br \/>\n            generations. The answer contains the distance expressed in tenths of a millimeter.\n        <\/p>\n<pre><code>Command sent: s0g Sensor response: g0g+00012345<\/code><\/pre>\n<p>\n            In this example, the sensor identifier is 0 and the transmitted distance is<br \/>\n            1,234.5 mm.\n        <\/p>\n<p>\n            The command <code>sNh<\/code> It also retains the same basic function: to initiate a<br \/>\n            Continuous measurement that remains active until the stop command is received<br \/>\n            <code>sNc<\/code>.\n        <\/p>\n<aside>\n<p>\n                <strong>Technical note:<\/strong> although the main commands maintain their<br \/>\n                In terms of name and general structure, some parameters show differences between<br \/>\n                generations. In timed commands <code>sNh+<\/code> and <code>sNf+<\/code>,<br \/>\n                The older DLS-C expresses the sampling time in units of 10 ms, while<br \/>\n                The current D series expresses this in milliseconds. The existing software should be reviewed.<br \/>\n                when using commands with additional parameters.\n            <\/p>\n<\/aside>\n<\/section>\n<section>\n<h2>Default communication parameters<\/h2>\n<p>\n            The series parameters used by default are equivalent in both<br \/>\n            generations:\n        <\/p>\n<ul>\n<li><strong>Speed:<\/strong> 19,200 baud.<\/li>\n<li><strong>Data bits:<\/strong> 7.<\/li>\n<li><strong>Parity:<\/strong> pair.<\/li>\n<li><strong>Stop bits:<\/strong> 1.<\/li>\n<\/ul>\n<p>\n            This coincidence facilitates the connection of the new sensor to systems that still use<br \/>\n            the original configuration of the DLS-C.\n        <\/p>\n<p>\n            However, before making a permanent replacement, the following must be checked:<br \/>\n            actual configuration of each installed sensor, since the communication parameters<br \/>\n            They may have been modified during initial commissioning.\n        <\/p>\n<\/section>\n<section>\n<h2>Comparison between Dimetix DLS-C 15 and DPE-10-500<\/h2>\n<div class=\"table-responsive\" style=\"overflow-x:auto;\">\n<table>\n<thead>\n<tr>\n<th>Feature<\/th>\n<th>Dimetix DLS-C 15<\/th>\n<th>Dimetrix DPE-10-500<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Product condition<\/td>\n<td>Old model discontinued<\/td>\n<td>Current model of the D series<\/td>\n<\/tr>\n<tr>\n<td>Typical accuracy, 2\u03c3<\/td>\n<td>\u00b11.5 mm<\/td>\n<td>\u00b11.0 mm<\/td>\n<\/tr>\n<tr>\n<td>Typical repeatability, 2\u03c3<\/td>\n<td>\u00b10.4 mm<\/td>\n<td>\u00b10.3 mm<\/td>\n<\/tr>\n<tr>\n<td>Maximum measurement frequency<\/td>\n<td>Up to 6 Hz<\/td>\n<td>Up to 250 Hz<\/td>\n<\/tr>\n<tr>\n<td>Maximum data output frequency<\/td>\n<td>Limited by the measurement frequency<\/td>\n<td>Up to 1 kHz<\/td>\n<\/tr>\n<tr>\n<td>Range on natural surfaces<\/td>\n<td>0.05 m to approximately 65 m<\/td>\n<td>0.05 m to approximately 100 m<\/td>\n<\/tr>\n<tr>\n<td>Reflector range<\/td>\n<td>Approximately 25\u2026150 m<\/td>\n<td>Approximately 0.5\u2026500 m<\/td>\n<\/tr>\n<tr>\n<td>RS-232<\/td>\n<td>Yeah<\/td>\n<td>Yeah<\/td>\n<\/tr>\n<tr>\n<td>RS-422<\/td>\n<td>Yeah<\/td>\n<td>Yeah<\/td>\n<\/tr>\n<tr>\n<td>RS-485<\/td>\n<td>No<\/td>\n<td>Yeah<\/td>\n<\/tr>\n<tr>\n<td>USB<\/td>\n<td>No<\/td>\n<td>Yes, via virtual COM port<\/td>\n<\/tr>\n<tr>\n<td>SSI<\/td>\n<td>Not in the DLS-C 15<\/td>\n<td>Yeah<\/td>\n<\/tr>\n<tr>\n<td>Analog output<\/td>\n<td>0\/4\u202620 mA<\/td>\n<td>0\/4\u202620 mA<\/td>\n<\/tr>\n<tr>\n<td>Nominal supply<\/td>\n<td>9\u202630 VDC<\/td>\n<td>12\u202630 VDC<\/td>\n<\/tr>\n<tr>\n<td>Operating temperature<\/td>\n<td>-10\u2026+50 \u00b0C<\/td>\n<td>-40\u2026+60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Degree of protection<\/td>\n<td>IP65<\/td>\n<td>IP65<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>150 \u00d7 80 \u00d7 55 mm<\/td>\n<td>140 \u00d7 78 \u00d7 48 mm<\/td>\n<\/tr>\n<tr>\n<td>Approximate weight<\/td>\n<td>690 g<\/td>\n<td>350 g<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<\/section>\n<section>\n<h2>Improved reading speed<\/h2>\n<p>\n            During the test, a faster response was observed from the new sensor. This improvement is<br \/>\n            consistent with the performance specifications for both generations.\n        <\/p>\n<p>\n            The older DLS-C 15 offers a maximum measurement frequency of up to 6 Hz, while<br \/>\n            that the DPE-10-500 can achieve up to 250 measurements per second and a frequency<br \/>\n            Maximum data output of 1 kHz, depending on the operating mode and the<br \/>\n            configuration used.\n        <\/p>\n<p>\n            The actual speed also depends on the reflectivity of the target, the distance,<br \/>\n            the environmental conditions, the measurement mode, and the speed set for the<br \/>\n            serial communication.\n        <\/p>\n<p>\n            In an older installation, using the maximum frequency is not mandatory. The system<br \/>\n            It can initially maintain a query speed similar to that used by the<br \/>\n            DLS-C 15 and subsequently take advantage of the greater capacity of the new sensor if the application<br \/>\n            It requires it.\n        <\/p>\n<\/section>\n<section>\n<h2>Validation result<\/h2>\n<p>The test confirmed the following points:<\/p>\n<ul>\n<li>The DPE-10-500 could be connected via USB to the existing computer.<\/li>\n<li>The USB driver was successfully installed on the tested Windows 7 computer.<\/li>\n<li>The sensor was recognized as a virtual COM serial port.<\/li>\n<li>Communication was successfully established on the first attempt.<\/li>\n<li>\n                It was possible to receive the distance values without modifying the main logic<br \/>\n                communication.\n            <\/li>\n<li>\n                The main distance acquisition commands are maintained between both<br \/>\n                generations.\n            <\/li>\n<li>The DPE-10-500 provided a superior read speed.<\/li>\n<li>\n                The results suggest a gradual replacement, after prior validation.<br \/>\n                each installation point.\n            <\/li>\n<\/ul>\n<p>\n            The result demonstrates that Dimetix has maintained significant consistency in the<br \/>\n            communication protocol. This compatibility facilitates the modernization of facilities<br \/>\n            that use DLS-C sensors and reduces the work required to adapt the software<br \/>\n            acquisition.\n        <\/p>\n<\/section>\n<section>\n<h2>Is the DPE-10-500 a direct replacement for the DLS-C 15?<\/h2>\n<p>\n            From the point of view of the measurement protocol, the<br \/>\n            <strong>DPE-10-500 offers a high level of compatibility with the DLS-C 15<\/strong>.<br \/>\n            However, it should not be considered a direct mechanical and electrical substitute without performing<br \/>\n            preliminary checks.\n        <\/p>\n<p>Before replacing a sensor, the following should be checked:<\/p>\n<ul>\n<li>The dimensions of the sensor and the mounting points.<\/li>\n<li>The position of the origin or measurement reference.<\/li>\n<li>The connector and the terminal assignment.<\/li>\n<li>The available supply voltage.<\/li>\n<li>The identifier configured on each sensor.<\/li>\n<li>The speed and format of serial communication.<\/li>\n<li>The commands used by the existing program.<\/li>\n<li>The parameters used in timed commands.<\/li>\n<li>The configuration of the analog and digital outputs.<\/li>\n<li>The maximum distance of the application.<\/li>\n<li>The surface on which the measurement is taken.<\/li>\n<\/ul>\n<p>\n            The DLS-C 15 supports a nominal power supply of 9 to 30 VDC, while the power supply<br \/>\n            The nominal voltage indicated for the DPE-10-500 is 12 to 30 VDC. The dimensions, weight, and<br \/>\n            The wiring and terminal layout are not identical either.\n        <\/p>\n<p>\n            Therefore, the technical conclusion is not that both sensors are physically interchangeable<br \/>\n            without any adaptation, but the DPE-10-500 allows<br \/>\n            <strong>maintain the protocol and main logic of distance acquisition<\/strong>,<br \/>\n            considerably reducing the complexity of modernization.\n        <\/p>\n<\/section>\n<section>\n<h2>Advantages obtained with the current D series<\/h2>\n<ul>\n<li>Reduction of the risk associated with the obsolescence of the DLS-C 15.<\/li>\n<li>Possibility of gradually replacing the sensors.<\/li>\n<li>Preservation of the main measurement commands.<\/li>\n<li>Less need to modify existing software.<\/li>\n<li>Greater accuracy and repeatability.<\/li>\n<li>Significant increase in reading speed.<\/li>\n<li>Greater range on natural and reflective surfaces.<\/li>\n<li>USB connection for configuration, diagnostics, and acquisition.<\/li>\n<li>RS-232 and RS-422\/485 compatibility.<\/li>\n<li>More compact housing and approximately 50% lighter than the %.<\/li>\n<li>Possibility of incorporating industrial communications in the new D series.<\/li>\n<\/ul>\n<p>\n            You can consult others<br \/>\n            <a href=\"https:\/\/guemisa.es\/en\/category\/laser-distance-sensor\/\"><br \/>\n                laser distance sensors<br \/>\n            <\/a><br \/>\n            available for industrial positioning, leveling, and control applications<br \/>\n            dimensional and automation.\n        <\/p>\n<\/section>\n<section>\n<h2>Conclusion<\/h2>\n<p>\n            The test carried out in a museum located in Catalonia demonstrates that an installation<br \/>\n            equipped with sensors <strong>Dimetix DLS-C 15<\/strong> can be modernized using<br \/>\n            sensors of the current D series without necessarily having to replace the software or<br \/>\n            completely modify the existing communication protocol.\n        <\/p>\n<p>\n            He <strong>Dimetrix DPE-10-500<\/strong> It maintained the structure of the main commands.<br \/>\n            The measurement device operated via a virtual COM port and provided a response<br \/>\n            considerably faster than the old model.\n        <\/p>\n<p>\n            In addition to communication compatibility, the new model offers greater precision,<br \/>\n            greater range, new interfaces, a more compact housing and a higher measurement frequency<br \/>\n            far superior.\n        <\/p>\n<p>\n            Each installation must be validated individually, especially regarding assembly,<br \/>\n            the power supply, the wiring, and the specific parameters used by the program.<br \/>\n            However, the continuity of the protocol reduces technical risk and facilitates migration<br \/>\n            from the old Dimetix DLS series to the current D series.\n        <\/p>\n<\/section>\n<section>\n<h2>Frequently asked questions about replacing the Dimetix DLS-C 15<\/h2>\n<h3>What model can replace the Dimetix DLS-C 15?<\/h3>\n<p>\n            The Dimetix DPE-10-500 can be used as a current alternative when a<br \/>\n            equal or superior accuracy, serial communication and a range of up to 500 m with reflector.<br \/>\n            The replacement must be validated because of the assembly, the wiring, and some parameters<br \/>\n            Electricians are different.\n        <\/p>\n<h3>Does the DPE-10-500 use the same commands as the DLS-C 15?<\/h3>\n<p>\n            The main commands used to take measurements, start tracking,<br \/>\n            Reading stored values and stopping the measurement maintain their name and structure<br \/>\n            general. Among them are <code>sNg<\/code>, <code>sNh<\/code>,<br \/>\n            <code>sNf<\/code>, <code>sNq<\/code> and <code>sNc<\/code>.\n        <\/p>\n<p>\n            Some additional parameters may use different units. For example, the<br \/>\n            Sampling times of timed commands are expressed in units of 10 ms in<br \/>\n            the old DLS-C and in milliseconds in the current D series.\n        <\/p>\n<h3>Can the program used with the DLS-C 15 be retained?<\/h3>\n<p>\n            In many cases, the main logic of distance acquisition can be preserved.<br \/>\n            However, it should be checked whether the program uses configuration commands, parameters<br \/>\n            timed functions, advanced features, analog outputs, digital inputs, or management<br \/>\n            error code developed specifically for the old sensor.\n        <\/p>\n<h3>Does the Dimetix DPE-10-500 work with Windows 7?<\/h3>\n<p>\n            In the test carried out in a museum located in Catalonia, the USB controller was installed<br \/>\n            It worked correctly, and the DPE-10-500 functioned on the existing Windows 7 computer.<br \/>\n            The result corresponds to the specific equipment used during the test and does not constitute<br \/>\n            a general certification for all Windows 7 systems.\n        <\/p>\n<h3>Does the DPE-10-500 connect directly in place of a DLS-C 15?<\/h3>\n<p>\n            Not necessarily. The protocol offers high compatibility, but they must<br \/>\n            Check the connector, terminal assignment, power supply, dimensions,<br \/>\n            the assembly and the reference from which the distance is measured.\n        <\/p>\n<h3>What speed improvement does the DPE-10-500 offer?<\/h3>\n<p>\n            The DLS-C 15 reaches a maximum frequency of up to 6 Hz. The DPE-10-500 can reach<br \/>\n            up to 250 Hz measurement frequency and a maximum data output frequency of<br \/>\n            1 kHz in certain configurations.\n        <\/p>\n<\/section>\n<footer>\n<h2>Do you need to replace a discontinued Dimetix DLS or FLS sensor?<\/h2>\n<p>\n            At GUEMISA we can analyze the installed model, the communication protocol, the<br \/>\n            wiring and measurement conditions to determine which current D-series sensor<br \/>\n            is more appropriate.\n        <\/p>\n<p>\n            Before making the replacement, we recommend checking the existing program, the<br \/>\n            Power supply, mechanical assembly and interfaces used in the installation.\n        <\/p>\n<p>\n            Browse our range of<br \/>\n            <a href=\"https:\/\/guemisa.es\/en\/category\/laser-distance-sensor\/\"><br \/>\n                laser distance sensors<br \/>\n            <\/a><br \/>\n            or contact our technical department.\n        <\/p>\n<p>\n            <a class=\"button\" href=\"https:\/\/guemisa.es\/en\/contact-guemisa\/\"><br \/>\n                Check the replacement of a Dimetix sensor<br \/>\n            <\/a>\n        <\/p>\n<\/footer>\n<\/article>","protected":false},"featured_media":7471,"template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"marca":[73],"industria":[],"class_list":["post-7468","casos-de-uso","type-casos-de-uso","status-publish","has-post-thumbnail","hentry","marca-dimetix"],"_links":{"self":[{"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/casos-de-uso\/7468","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/casos-de-uso"}],"about":[{"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/types\/casos-de-uso"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/media\/7471"}],"wp:attachment":[{"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/media?parent=7468"}],"wp:term":[{"taxonomy":"marca","embeddable":true,"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/marca?post=7468"},{"taxonomy":"industria","embeddable":true,"href":"https:\/\/guemisa.es\/en\/wp-json\/wp\/v2\/industria?post=7468"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}