Dimetix D-Series Laser Distance Sensors: Accuracy and Reliability in Every Measurement Dimetix D-Series laser distance sensors represent the latest in technology and innovation. Designed to measure long distances with maximum accuracy, these sensors excel in reliability and speed, even in the most demanding environments. The Dimetix D-Series is ideal for industrial applications, as it can make accurate measurements on dark surfaces and even outdoors under intense sunlight conditions. Thanks to their 1 kHz output frequency, these sensors offer superior performance in tasks that require a high response speed. Discover how D-Series laser distance sensors can optimize your industrial processes.

Properties

Accuracy 2σ (1σ) ±5 (±2.5) mm
Repeatability 2σ (1σ) ±1.8(±0.9) mm
Measuring range on natural surfaces 0.05…~50 m
Measuring range on reflective film –
Max. measuring speed 10 Hz
Max output speed 10 Hz
Operating temperature -10…+50°C
IP65 protection grade
Power supply 12…30 VDC(0.15A @ 24 VDC)
Red laser, visible (Class 2 laser, <1 mW) ✓
Typical laser spot diameter at 10, 50, 100 m 7 x 3 mm; 28 x 13 mm; 55 x 30 mm
Dimensions (length x width x height) 140 x 78 x 48 mm
Weight 350 g

Dimetix Laser Sensor DPE-10-500, DPE-30-500, DEN-10-500, DEH-30-500, DAE-10-050, DAN-10-150, DAN-30-150, DBN-50-050

Other products

B&C Electronics Logo
Cell content K=1cm-1 (2 to 2,000µS) Thread 1″ BSP, body material PVC
TDC, digital MEMS dynamic tilt sensor, can measure (roll ±180°, pitch ±180°, and azimuth ±180°) of a moving object. RS485 output signal. Withstands vibrations up to 2000g
Dimetix_AG-1
Non-contact laser distance sensor Model DEH-30-500
I/41Q – Miniature Incremental Encoder, Shaft Ø 6.35×14 mm, Body: Ø 40×52.5 mm, Pulse range: 1 to 2,540
B&C Electronics Logo
Conductivity sensor, CLAMP connection, K range = 0.1, temperature range -5 to 85ºC
Dimetix_AG-1
Reflective film 600 x 1200 mm For Dimetix laser sensor
Flush diaphragm pressure transducer (supply)
Tension/compression load cell