{"id":13640,"date":"2026-11-02T14:44:09","date_gmt":"2026-11-02T13:44:09","guid":{"rendered":"https:\/\/guemisa.es\/?p=13640"},"modified":"2026-11-03T11:10:29","modified_gmt":"2026-11-03T10:10:29","slug":"lvdt-assaigs-laboratori","status":"publish","type":"post","link":"https:\/\/guemisa.es\/ca\/lvdt-ensayos-laboratorio\/","title":{"rendered":"LVDT per a assaigs de laboratori: precisi\u00f3, carrera i condicionador"},"content":{"rendered":"<div class=\"gm-guia\"><p class=\"gm-g-kicker\">Guia t\u00e8cnica \u00b7 GUEMISSA<\/p><div class=\"gm-g-resp\"><span>Resposta r\u00e0pida<\/span><p>Per a un assaig de laboratori, un LVDT passiu amb condicionador extern \u00e9s l'opci\u00f3 quan importen la resoluci\u00f3, la mida del sensor o el rang de temperatura, i un LVDT amplificat (amb l'electr\u00f2nica dins de la carcassa) ho \u00e9s quan es prefereix connectar el sensor directament a una entrada normalitzada de 4\u202620 mA o 0\u202610 V. aquesta cursa: com m\u00e9s curta la cursa, menor l'error absolut.<\/p>\n<p>Un LVDT (transformador diferencial de variaci\u00f3 lineal) mesura despla\u00e7aments sense contacte el\u00e8ctric entre el nucli i les bobines, de manera que no hi ha fregament ni desgast a la mesura.<\/p><\/div><figure class=\"gm-anim\" data-anim=\"lvdt\"><figcaption class=\"gm-anim-pie\">El primari s'excita en alterna; en moure el nucli canvia la tensi\u00f3 de cada secundari i l'electr\u00f2nica d\u00f3na una sortida lineal amb el zero al centre.<\/figcaption><\/figure><nav class=\"gm-g-indice\"><b>En aquesta guia<\/b><ol><li><a href=\"#principio-de-funcionamiento\">Principi de funcionament<\/a><\/li><li><a href=\"#lvdt-amplificado-frente-a-lvdt-pasivo-con-acondicionador\">LVDT amplificat davant de LVDT passiu amb condicionador<\/a><\/li><li><a href=\"#carrera-y-linealidad\">Cursa i linealitat<\/a><\/li><li><a href=\"#retorno-por-muelle-o-nucleo-libre\">Retorn per moll o nucli lliure<\/a><\/li><li><a href=\"#palpadores-y-puntas-de-medida\">Palpadors i puntes de mesura<\/a><\/li><li><a href=\"#comparativa-de-productos\">Comparativa de productes<\/a><\/li><li><a href=\"#que-productos-de-guemisa-encajan\">Quins productes de GUEMISA encaixen<\/a><\/li><li><a href=\"#preguntas-frecuentes\">Preguntes freq\u00fcents<\/a><\/li><\/ol><\/nav><h2 id=\"principio-de-funcionamiento\">Principi de funcionament<\/h2>\n<p>El sensor porta un debanat primari i dos secundaris connectats en oposici\u00f3. Un oscil\u00b7lador excita el primari amb corrent altern; a les s\u00e8ries passives de Schreiber, per exemple, la freq\u00fc\u00e8ncia d'excitaci\u00f3 \u00e9s de 10 kHz. Dins del conjunt es despla\u00e7a un nucli d'aliatge ferromagn\u00e8tic (Ni-Fe) unit a un plan\u00e7\u00f3:<\/p>\n<ul>\n<li>amb el nucli al centre, les tensions dels dos secundaris s'anul\u00b7len i la sortida \u00e9s zero;<\/li>\n<li>en despla\u00e7ar el nucli, una tensi\u00f3 creix i l'altra disminueix; la difer\u00e8ncia \u00e9s proporcional al despla\u00e7ament;<\/li>\n<li>el sentit del moviment ho indica la fase del senyal respecte a l'excitaci\u00f3.<\/li>\n<\/ul>\n<p>Com que el senyal \u00e9s continu a l'espai, la resoluci\u00f3 del propi sensor \u00e9s te\u00f2ricament infinita; a la pr\u00e0ctica la limita el soroll de l'electr\u00f2nica i de l'adquisici\u00f3.<\/p>\n\n<h2 id=\"lvdt-amplificado-frente-a-lvdt-pasivo-con-acondicionador\">LVDT amplificat davant de LVDT passiu amb condicionador<\/h2>\n<p>La difer\u00e8ncia no \u00e9s al principi de mesura, sin\u00f3 on va l'electr\u00f2nica d'excitaci\u00f3 i demodulaci\u00f3.<\/p>\n<div class=\"gm-g-tabla\"><table>\n<thead>\n<tr><th>Aspecte<\/th><th>LVDT amplificat<\/th><th>LVDT passiu + condicionador<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>Electr\u00f2nica<\/td><td>Integrada al sensor<\/td><td>M\u00f2dul extern (carril DIN o OEM)<\/td><\/tr>\n<tr><td>Sortida<\/td><td>Normalitzada: 4\u202620 mA, 0\u202620 mA, 0\u202610 V, \u00b110 V<\/td><td>Senyal AC de baixa amplitud al sensor; el m\u00f2dul d\u00f3na 0\/4\u202620 mA, 0\u202610 V o \u00b110 V<\/td><\/tr>\n<tr><td>Alimentaci\u00f3<\/td><td>Continua (per exemple 18\u202630 VDC o 24 VDC)<\/td><td>Nom\u00e9s el m\u00f2dul condicionador<\/td><\/tr>\n<tr><td>Cablejat entre sensor i sistema<\/td><td>Senyal normalitzat, menys sensible al soroll<\/td><td>Cable curt i apantallat fins al m\u00f2dul<\/td><\/tr>\n<tr><td>Grand\u00e0ria del sensor<\/td><td>Dep\u00e8n del model; hi ha amplificats des de \u00d8 10 mm (Schreiber SM27)<\/td><td>Molt redu\u00eft, des de \u00d8 10 mm a Schreiber SM21 i SM210<\/td><\/tr>\n<tr><td>Ajust<\/td><td>Segons model (algunes s\u00e8ries permeten escalar la sortida)<\/td><td>Guany i zero al m\u00f2dul<\/td><\/tr>\n<tr><td>Quan encaixa<\/td><td>Instrumentaci\u00f3 i adquisici\u00f3 amb entrades anal\u00f2giques est\u00e0ndard<\/td><td>Espais redu\u00efts, temperatures extremes o diversos sensors amb un mateix condicionador<\/td><\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>En assajos amb molta longitud de cable o amb soroll el\u00e8ctric de motors i variadors, la sortida amplificada en corrent sol resultar m\u00e9s c\u00f2moda. En provetes petites o en c\u00e0meres clim\u00e0tiques, el sensor passiu es pot col\u00b7locar a l'interior i deixar el condicionador fora.<\/p>\n\n<h2 id=\"carrera-y-linealidad\">Cursa i linealitat<\/h2>\n<h3>Com triar la cursa<\/h3>\n<p>Escolliu la cursa est\u00e0ndard immediatament superior al despla\u00e7ament m\u00e0xim esperat, incloses les posicions d'ajust. Un rang excessiu redueix la sensibilitat i, amb ella, el senyal \u00fatil a les deformacions petites; un massa ajustat porta el nucli als extrems, on la linealitat \u00e9s pitjor. Les dades de fitxa usen carrera el\u00e8ctrica (el tram en qu\u00e8 es garanteix la linealitat) i carrera mec\u00e0nica (el recorregut f\u00edsic total): a l'FTI 10, per exemple, 10 mm i 12 mm.<\/p>\n<h3>Com llegir la linealitat<\/h3>\n<p>S'expressa en percentatge del fons d'escala. Un LVDT de 20 mm amb \u00b10,25 % t\u00e9 un error de \u00b10,05 mm, \u00e9s a dir \u00b150 \u00b5m; el mateix percentatge en un sensor de 5 mm d\u00f3na \u00b112,5 \u00b5m. La repetibilitat sol ser molt inferior a l'error de linealitat: l'FTI 10 declara una repetibilitat t\u00edpica inferior a 2 micres, i el palpador Schreiber SM224 una repetibilitat m\u00e0xima de 0,15 micres. Per a assajos en qu\u00e8 es comparen mesures entre si, la repetibilitat pesa m\u00e9s que la linealitat absoluta.<\/p>\n<h3>Resoluci\u00f3<\/h3>\n<p>El sensor no en limita la resoluci\u00f3; s\u00ed que ho fan el condicionador, el convertidor anal\u00f2gic-digital i el soroll. Els condicionadors Schreiber de la s\u00e8rie SM12 declaren una deriva t\u00e8rmica inferior a 0,005 %\/\u00b0C i una freq\u00fc\u00e8ncia de tall de 800 Hz, dades que cal mirar segons la velocitat de l'assaig.<\/p>\n\n<h2 id=\"retorno-por-muelle-o-nucleo-libre\">Retorn per moll o nucli lliure<\/h2>\n<div class=\"gm-g-tabla\"><table>\n<thead>\n<tr><th>Configuraci\u00f3<\/th><th>Com treballa<\/th><th>Quan conv\u00e9<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>Nucli lliure<\/td><td>El nucli s'uneix mec\u00e0nicament a la pe\u00e7a i es mou dins el cos sense tocar les parets<\/td><td>Assajos din\u00e0mics o amb espais molt ajustats i on no s'admet for\u00e7a de contacte sobre la mostra<\/td><\/tr>\n<tr><td>Palpador amb tornada per moll<\/td><td>La tija es recolza contra la pe\u00e7a amb una for\u00e7a definida<\/td><td>Mesuraments puntuals de cota, gruix o deformaci\u00f3, sense acoblar la tija a la pe\u00e7a<\/td><\/tr>\n<tr><td>Retorn pneum\u00e0tic (SM224, opci\u00f3 .P)<\/td><td>La for\u00e7a ajusta la pressi\u00f3: 0,4 bar equivalen a 0,7 N i 1 bar a 2,5 N<\/td><td>Quan cal controlar i reduir la for\u00e7a de contacte<\/td><\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>La for\u00e7a de contacte afecta la mida si la pe\u00e7a \u00e9s tova o prima. A les dades de GUEMISA, el palpador Schreiber SM224 aplica uns 0,7 N al centre del recorregut, el LVDT amb retorn FTI 10 de Novotechnik necessita 4 N amb IP50 i 10 N amb IP67, i l'F200 de Novotechnik, menys de 2 N.<\/p>\n\n<h2 id=\"palpadores-y-puntas-de-medida\">Palpadors i puntes de mesura<\/h2>\n<p>La punta \u00e9s la pe\u00e7a que toca la mostra i en condiciona el resultat. Els palpadors Schreiber SM22 i SM224 porten rosca M2,5 a la punta; el F200 se subministra amb un palpador roscat amb punta de metall dur i contrafemella, que permet unir-lo per fricci\u00f3 a l'objecte. Si la punta \u00e9s de metall dur, el desgast \u00e9s menor amb superf\u00edcies abrasives. Una manxa protegeix la tija de pols i esquitxades (l'SM224 declara IP65 amb manxa). Tingueu en compte que la for\u00e7a del moll i el pes de la tija limiten la velocitat a qu\u00e8 el palpador segueix la superf\u00edcie sense perdre contacte.<\/p>\n\n<h2 id=\"comparativa-de-productos\">Comparativa de productes<\/h2>\n<div class=\"gm-g-tabla\"><table>\n<thead>\n<tr><th>Producte<\/th><th>Tipus<\/th><th>Cursa<\/th><th>Linealitat<\/th><th>Sortida<\/th><th>Protecci\u00f3<\/th><\/tr>\n<\/thead>\n<tbody>\n<tr><td>Novotechnik F200<\/td><td>Amplificat, plan\u00e7\u00f3<\/td><td>5, 10 o 20 mm (el\u00e8ctrica)<\/td><td>\u00b10,1 a \u00b10,3 %<\/td><td>\u00b110 VDC<\/td><td>IP67 amb connector EEM<\/td><\/tr>\n<tr><td>Novotechnik FTI 10<\/td><td>Amplificat, amb retorn<\/td><td>10 mm (el\u00e8ctrica)<\/td><td>\u00b10,1, \u00b10,2 o \u00b10,4 %<\/td><td>4\u202620 mA o 0\u202620 mA<\/td><td>IP50 o IP67<\/td><\/tr>\n<tr><td>Schreiber SM21<\/td><td>Passiu<\/td><td>5 a 20 mm<\/td><td>menys de 0,5% (0,25% opcional)<\/td><td>AC, amb condicionador<\/td><td>IP66 o IP68<\/td><\/tr>\n<tr><td>Schreiber SM26\/SM28<\/td><td>Passiu<\/td><td>24 a 360 mm<\/td><td>menys de 0,5% (0,25% opcional)<\/td><td>AC, amb condicionador<\/td><td>IP66 amb connector, fins a IP68 amb cable<\/td><\/tr>\n<tr><td>Schreiber SM224<\/td><td>Palpador passiu<\/td><td>2, 5, 10 o 20 mm<\/td><td>menys de 0,5% (0,25% opcional)<\/td><td>AC, amb condicionador<\/td><td>IP65 amb manxa<\/td><\/tr>\n<tr><td>Schreiber SM30<\/td><td>Amplificat<\/td><td>5, 10 o 15 mm<\/td><td>\u00b10,5 % (\u00b10,25 % opcional)<\/td><td>4\u202620 mA, 0\u202620 mA, \u00b110 V, 0\u202610 V<\/td><td>IP66 amb connector M12, IP68 amb cable<\/td><\/tr>\n<tr><td>Schreiber SM41\/SM43<\/td><td>Amplificat i programable<\/td><td>20 a 360 mm<\/td><td>0,2% (fins a 0,1% amb correcci\u00f3)<\/td><td>4\u202620 mA, 0\u202620 mA, 0\u202610 V, 0\u20265 V<\/td><td>IP67, IP68 amb cable<\/td><\/tr>\n<\/tbody>\n<\/table><\/div>\n\n<h2 id=\"que-productos-de-guemisa-encajan\">Quins productes de GUEMISA encaixen<\/h2>\n<div class=\"gm-g-cards\"><a class=\"gm-g-card\" href=\"https:\/\/guemisa.es\/ca\/productes\/transductor-de-posicio-inductiu-f200\/\"><span class=\"gm-g-foto\"><img decoding=\"async\" src=\"https:\/\/guemisa.es\/wp-content\/uploads\/2026\/10\/novotechnik-transductor-posicion-inductivo-f200-300x225.webp\" alt=\"F200 de Novotechnik\" loading=\"lazy\"><\/span><b>F200 de Novotechnik<\/b><span class=\"gm-g-datos\">curses el\u00e8ctriques de 5, 10 i 20 mm, sortida de \u00b110 VDC, linealitat de \u00b10,1 a \u00b10,3 % i resoluci\u00f3 gaireb\u00e9 infinita.<\/span><em>Veure fitxa t\u00e8cnica \u2192<\/em><\/a><a class=\"gm-g-card\" href=\"https:\/\/guemisa.es\/ca\/productes\/transductor-inductiu-de-posicio-fti-10\/\"><span class=\"gm-g-foto\"><img decoding=\"async\" src=\"https:\/\/guemisa.es\/wp-content\/uploads\/2026\/11\/novotechnik-fti-10-sensor-inductivo-desplazamiento-lineal.webp-768x595.webp\" alt=\"FTI 10 de Novotechnik\" loading=\"lazy\"><\/span><b>FTI 10 de Novotechnik<\/b><span class=\"gm-g-datos\">cursa el\u00e8ctrica de 10 mm, sortida de 4\u202620 mA o 0\u202620 mA, repetibilitat t\u00edpica inferior a 2 \u00b5m i IP50 o IP67.<\/span><em>Veure fitxa t\u00e8cnica \u2192<\/em><\/a><a class=\"gm-g-card\" href=\"https:\/\/guemisa.es\/ca\/productes\/lvdt-lineal-schreiber-sm26-sm28\/\"><span class=\"gm-g-foto\"><img decoding=\"async\" src=\"https:\/\/guemisa.es\/wp-content\/uploads\/2025\/01\/Sm26A-768x508.jpg\" alt=\"Schreiber SM26 i SM28\" loading=\"lazy\"><\/span><b>Schreiber SM26 i SM28<\/b><span class=\"gm-g-datos\">LVDT passiu de 24 a 360 mm, nucli lliure o palpador amb moll; es combina amb els condicionadors de la s\u00e8rie SM10 i SM12.<\/span><em>Veure fitxa t\u00e8cnica \u2192<\/em><\/a><a class=\"gm-g-card\" href=\"https:\/\/guemisa.es\/ca\/productes\/palpador-lvdt-schreiber-sm224\/\"><span class=\"gm-g-foto\"><img decoding=\"async\" src=\"https:\/\/guemisa.es\/wp-content\/uploads\/2025\/01\/SM224-768x589.jpg\" alt=\"Schreiber SM224\" loading=\"lazy\"><\/span><b>Schreiber SM224<\/b><span class=\"gm-g-datos\">palpador de 2 a 20 mm amb repetibilitat m\u00e0xima de 0,15 micres i opci\u00f3 d'accionament pneum\u00e0tic.<\/span><em>Veure fitxa t\u00e8cnica \u2192<\/em><\/a><a class=\"gm-g-card\" href=\"https:\/\/guemisa.es\/ca\/productes\/sensor-lvdt-amplificat-sm41-sm43\/\"><span class=\"gm-g-foto\"><img decoding=\"async\" src=\"https:\/\/guemisa.es\/wp-content\/uploads\/2026\/03\/sensor-lvdt-escalable-amplificado-schreiber-sm41-sm43-300x63.jpg\" alt=\"Schreiber SM41 i SM43\" loading=\"lazy\"><\/span><b>Schreiber SM41 i SM43<\/b><span class=\"gm-g-datos\">LVDT amplificat de 20 a 360 mm, carcassa d\u00b4acer inoxidable \u00d8 25 mm, sortida escalable.<\/span><em>Veure fitxa t\u00e8cnica \u2192<\/em><\/a><a class=\"gm-g-card\" href=\"https:\/\/guemisa.es\/ca\/productes\/convertidor-lvdt-schreiber-sm12\/\"><span class=\"gm-g-foto\"><img decoding=\"async\" src=\"https:\/\/guemisa.es\/wp-content\/uploads\/2024\/12\/Amplificador-LVDT-300x170.jpg\" alt=\"Schreiber SM12\" loading=\"lazy\"><\/span><b>Schreiber SM12<\/b><span class=\"gm-g-datos\">condicionador en carril DIN amb sortides de 0\/4\u202620 mA, 0\u202610 V o \u00b110 V per a LVDT passius.<\/span><em>Veure fitxa t\u00e8cnica \u2192<\/em><\/a><\/div><div class=\"gm-g-chips\"><a class=\"gm-g-chip\" href=\"https:\/\/guemisa.es\/ca\/categoria\/lvdt\/\">Categoria Sensors LVDT<\/a><\/div>\n\n<h2 id=\"documentacion-relacionada\">Documentaci\u00f3 i casos relacionats<\/h2><ul class=\"gm-g-rel\"><li><a href=\"https:\/\/guemisa.es\/ca\/documents-pdf\/explicacio-tecnica-que-es-una-lvdt\/\">LVDT: qu\u00e8 \u00e9s i com funciona (PDF)<\/a><\/li><li><a href=\"https:\/\/guemisa.es\/ca\/documents-pdf\/cataleg-sensors-lvdt-schreiber-messtechnik\/\">Cat\u00e0leg de sensors LVDT Schreiber Messtechnik (PDF)<\/a><\/li><li><a href=\"https:\/\/guemisa.es\/ca\/informacio-tecnica\/\">Tota la informaci\u00f3 t\u00e8cnica de GUEMISA<\/a><\/li><\/ul><h2 id=\"preguntas-frecuentes\">Preguntes freq\u00fcents<\/h2>\n<details class=\"gm-g-faq\"><summary>Quina difer\u00e8ncia hi ha entre un LVDT amplificat i un de passiu?<\/summary><p>L'amplificat porta l'electr\u00f2nica d'excitaci\u00f3 i demodulaci\u00f3 dins del sensor i lliura 4\u202620 mA o una tensi\u00f3 normalitzada. El passiu lliura un senyal alterna i necessita un condicionador extern.<\/p>\n<\/details><details class=\"gm-g-faq\"><summary>Quina precisi\u00f3 t\u00e9 un LVDT?<\/summary><p>Dep\u00e8n del model. A les fitxes de GUEMISA la linealitat va de \u00b10,1 % a l'F200 i l'FTI 10 a menys de 0,5 % als passius est\u00e0ndard, i es refereix sempre al fons d'escala de la carrera.<\/p>\n<\/details><details class=\"gm-g-faq\"><summary>Puc fer servir un LVDT passiu amb un PLC?<\/summary><p>S\u00ed, per\u00f2 necessita un condicionador entre tots dos que converteixi el senyal alterna a 4\u202620 mA o 0\u202610 V, com els m\u00f2duls Schreiber SM12.<\/p>\n<\/details><details class=\"gm-g-faq\"><summary>Quan trio nucli lliure i quan palpador?<\/summary><p>El nucli lliure es fa servir quan es pot unir la tija a la pe\u00e7a i no es vol for\u00e7a de contacte. El palpador amb moll serveix per mesurar sense fixar el plan\u00e7\u00f3, a canvi d'una for\u00e7a de contacte entre 0,7 N i 10 N segons el model.<\/p>\n<\/details><details class=\"gm-g-faq\"><summary>Un LVDT pateix desgast?<\/summary><p>El nucli no toca les bobines, de manera que la mesura no produeix desgast intern. Als palpadors, el desgast es concentra a la punta i al guiatge de la tija.<\/p><\/details>\n\n<div class=\"gm-g-cta\"><b>Necessiteu ajuda per triar?<\/b><p>Envieu-nos l'aplicaci\u00f3, la cursa o la refer\u00e8ncia que teniu i us indiquem el model i el vostre codi de comanda.<\/p><p><a class=\"gm-g-btn\" href=\"mailto:ventas@guemisa.com?subject=Consulta%3A%20LVDT%20para%20ensayos%20de%20laboratorio%3A%20precisi%C3%B3n%2C%20carrera%20y%20acondicionador\">Escriure a ventas@guemisa.com<\/a> <a class=\"gm-g-btn gm-g-btn2\" href=\"tel:+34917642100\">91 764 21 00<\/a><\/p><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>LVDT amplificat o passiu amb condicionador: principi, carrera, linealitat, retorn per moll o nucli lliure i palpadors per a assaigs de laboratori.<\/p>","protected":false},"author":1,"featured_media":13790,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[710],"tags":[],"class_list":["post-13640","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-guias-tecnicas"],"_links":{"self":[{"href":"https:\/\/guemisa.es\/ca\/wp-json\/wp\/v2\/posts\/13640","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/guemisa.es\/ca\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/guemisa.es\/ca\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/guemisa.es\/ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/guemisa.es\/ca\/wp-json\/wp\/v2\/comments?post=13640"}],"version-history":[{"count":5,"href":"https:\/\/guemisa.es\/ca\/wp-json\/wp\/v2\/posts\/13640\/revisions"}],"predecessor-version":[{"id":13931,"href":"https:\/\/guemisa.es\/ca\/wp-json\/wp\/v2\/posts\/13640\/revisions\/13931"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/guemisa.es\/ca\/wp-json\/wp\/v2\/media\/13790"}],"wp:attachment":[{"href":"https:\/\/guemisa.es\/ca\/wp-json\/wp\/v2\/media?parent=13640"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/guemisa.es\/ca\/wp-json\/wp\/v2\/categories?post=13640"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/guemisa.es\/ca\/wp-json\/wp\/v2\/tags?post=13640"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}